Frame | Product Type | Single Pane 3, 4 U-Factor | Double Pane 1, 3, 4 U-Factor | Glass Block 2,3 U-Factor |
Metal | Operable | 1.28 | 0.79 | 0.87 |
Metal | Fixed | 1.19 | 0.71 | 0.72 |
Metal | Greenhouse/Garden Window | 2.26 | 1.40 | N.A. |
Metal | Glazed Doors | 1.25 | 0.77 | N.A. |
Metal | Skylight | 1.98 | 1.30 | N.A. |
Metal, Thermal Break | Operable | N.A. | 0.66 | N.A. |
Metal, Thermal Break | Fixed | N.A. | 0.55 | N.A. |
Metal, Thermal Break | Greenhouse/Garden Window | N.A. | 1.12 | N.A. |
Metal, Thermal Break | Glazed Doors | N.A. | 0.59 | N.A. |
Metal, Thermal Break | Skylight | N.A. | 1.11 | N.A. |
Nonmetal | Operable | 0.99 | 0.58 | 0.60 |
Nonmetal | Fixed | 1.04 | 0.55 | 0.57 |
Nonmetal | Glazed Doors | 0.99 | 0.53 | N.A. |
Nonmetal | Greenhouse/Garden Windows | 1.94 | 1.06 | N.A. |
Nonmetal | Skylight | 1.47 | 0.84 | N.A. |
1. For all dual-glazed fenestration products, adjust the listed U-factors as follows: a. Add 0.05 for products with dividers between panes if spacer is less than 7/16 inch wide. b. Add 0.05 to any product with true divided lite (dividers through the panes). 2. Translucent or transparent panels shall use glass block values when not rated by NFRC 100. 3. Visible Transmittance (VT) shall be calculated by using Reference Nonresidential Appendix NA6. 4. Windows with window film applied that is not rated by NFRC 100 shall use the default values from this table. |
FRAME TYPE
|
PRODUCT
|
GLAZING
|
FENESTRATION PRODUCT SHGC Single Pane 2,3
SHGC |
FENESTRATION PRODUCT SHGC Double Pane 2,3
SHGC |
FENESTRATION PRODUCT SHGC Glass Block 1,2
SHGC |
Metal
|
Operable
|
Clear
|
0.80
|
0.70
|
0.70
|
Metal
|
Fixed
|
Clear
|
0.83
|
0.73
|
0.73
|
Metal
|
Operable
|
Tinted
|
0.67
|
0.59
|
N.A.
|
Metal
|
Fixed
|
Tinted
|
0.68
|
0.60
|
N.A.
|
Metal, Thermal Break
|
Operable
|
Clear
|
N.A.
|
0.63
|
N.A.
|
Metal, Thermal Break
|
Fixed
|
Clear
|
N.A.
|
0.69
|
N.A.
|
Metal, Thermal Break
|
Operable
|
Tinted
|
N.A.
|
0.53
|
N.A.
|
Metal, Thermal Break
|
Fixed
|
Tinted
|
N.A.
|
0.57
|
N.A.
|
Nonmetal
|
Operable
|
Clear
|
0.74
|
0.65
|
0.70
|
Nonmetal
|
Fixed
|
Clear
|
0.76
|
0.67
|
0.67
|
Nonmetal
|
Operable
|
Tinted
|
0.60
|
0.53
|
N.A.
|
Nonmetal
|
Fixed
|
Tinted
|
0.63
|
0.55
|
N.A.
|
1. Translucent or transparent panels shall use glass block values when not rated by NFRC 200.
2. Visible Transmittance (VT) shall be calculated by using Reference Nonresidential Appendix NA6. 3. Windows with window film applied that is not rated by NFRC 200 shall use the default values from this table. |