JA2.2 - California Design Location Data
The data contained in the following table was obtained through a joint effort by the Southern California Chapter and the Golden Gate Chapter of ASHRAE. It is reprinted here with the written permission of Southern California Chapter ASHRAE, Inc. The values for 1.0 percent drybulb and 1.0 percent mean coincident wetbulb (MCWB) are interpolated.
The data in Table 2-3 is developed from Aa full listing of design location data for California is contained in the ASHRAE publication SPCDX, Climate Data for Region X, Arizona, California, Hawaii, and Nevada (ISBN 200021, May 1982) and Supplement to Climatic Data for Region X, Arizona, California, Hawaii, Nevada (ISBN 20002956, November 1994). The publication may be ordered from:
Order Desk
Building News
10801 National Blvd.
Los Angeles, CA 90064
(888) 264-7483 or (310) 474-7771
http://www.bnibooks.com
Please click on the link below to view Table 2-3
Table 2-3 – Design Day Data for California Cities
City | Latitude | Elevation (ft) | Longitude | Cooling | Heating | |||||||||||||
0.10% | 0.50% | 1.00% | 2.00% | Design Wetbulb 0.1% | Design Wetbulb 0.5% | Outdoor Daily Range | Winter Median of Extremes | Design Drybulb (0.2%) | Design Drybulb (0.6%) | HDD* | ||||||||
DB | MCWB | DB | MCWB | DB | MCWB | DB | MCWB | |||||||||||
Adelanto | 34.6 | 2865 | 117.4 | 105 | 67 | 101 | 65 | 100 | 64 | 97 | 62 | 70 | 68 | 39 | 14 | 24 | 27 | 1654 |
din RS | 41.2 | 4195 | 121 | 96 | 61 | 92 | 60 | 91 | 60 | 88 | 59 | 65 | 63 | 43 | -7 | -2 | 4 | - |
Agoura Hills | 34.2 | 700 | 118.8 | 103 | 70 | 96 | 68 | 94 | 68 | 90 | 66 | 73 | 71 | 29 | 27 | 31 | 34 | - |
Alameda NAS | 37.8 | 15 | 122.3 | 88 | 65 | 82 | 64 | 80 | 64 | 76 | 62 | 66 | 64 | 21 | 35 | 38 | 40 | 2507 |
Alamo | 37.9 | 410 | 122.9 | 102 | 69 | 97 | 68 | 96 | 68 | 92 | 66 | 72 | 70 | 30 | 23 | 28 | 31 | - |
Albany | 37.9 | 40 | 122.3 | 88 | 65 | 83 | 64 | 81 | 64 | 77 | 62 | 66 | 64 | 16 | 30 | 35 | 38 | - |
Alderpoint | 40.2 | 460 | 123.6 | 100 | 69 | 95 | 67 | 94 | 67 | 90 | 65 | 70 | 68 | 39 | 21 | 27 | 30 | 3424 |
Alhambra | 34 | 483 | 118.1 | 100 | 71 | 96 | 70 | 94 | 70 | 90 | 68 | 73 | 71 | 25 | 30 | 35 | 37 | - |
Aliso Viejo | 33.6 | 50 | 117.7 | 91 | 69 | 83 | 68 | 81 | 68 | 76 | 66 | 71 | 69 | 18 | 30 | 33 | 36 | - |
Almaden AFS | 37.2 | 3470 | 121.9 | 95 | 62 | 90 | 60 | 89 | 60 | 85 | 59 | 64 | 62 | 20 | 20 | 25 | 29 | 4468 |
Alondra Park | 33.9 | 50 | 118.3 | 91 | 69 | 86 | 68 | 85 | 68 | 81 | 66 | 71 | 69 | 17 | 35 | 40 | 42 | - |
Alpine | 32.8 | 1735 | 116.8 | 99 | 69 | 95 | 68 | 94 | 68 | 91 | 67 | 72 | 70 | 35 | 27 | 32 | 35 | - |
Alta Sierra | 35.7 | 6500 | 118.6 | 87 | 62 | 84 | 61 | 83 | 61 | 80 | 59 | 65 | 63 | 32 | -4 | 1 | 8 | 2428 |
Altadena | 34.2 | 1200 | 118.1 | 99 | 68 | 94 | 67 | 92 | 67 | 88 | 66 | 72 | 70 | 31 | 32 | 37 | 39 | 1920 |
Alturas RS | 41.5 | 4400 | 120.6 | 99 | 62 | 96 | 61 | 95 | 61 | 91 | 59 | 65 | 63 | 43 | -10 | -4 | 0 | 6895 |
Alum Rock | 37.4 | 70 | 121.8 | 95 | 68 | 90 | 66 | 88 | 66 | 84 | 64 | 70 | 68 | 22 | 28 | 33 | 36 | - |
American Canyon | 37.6 | 85 | 122.3 | 93 | 67 | 90 | 66 | 88 | 66 | 84 | 64 | 70 | 68 | 23 | 28 | 33 | 36 | - |
Anaheim | 33.8 | 158 | 117.9 | 99 | 69 | 92 | 68 | 90 | 68 | 85 | 67 | 73 | 71 | 26 | 32 | 37 | 39 | - |
Anderson | 40.5 | 430 | 122.3 | 107 | 71 | 103 | 70 | 101 | 70 | 97 | 68 | 72 | 70 | 30 | 26 | 31 | 34 | - |
Angwin | 38.6 | 1815 | 122.4 | 98 | 66 | 93 | 64 | 92 | 64 | 88 | 62 | 69 | 66 | 33 | 25 | 30 | 33 | - |
Antioch | 38 | 60 | 121.8 | 102 | 70 | 97 | 68 | 95 | 68 | 91 | 66 | 70 | 69 | 34 | 22 | 28 | 31 | 2627 |
Apple Valley | 34.5 | 2935 | 117.2 | 105 | 66 | 101 | 65 | 100 | 65 | 97 | 64 | 70 | 68 | 38 | 14 | 21 | 25 | - |
Aptos | 37 | 500 | 121.9 | 94 | 67 | 88 | 66 | 87 | 65 | 83 | 63 | 69 | 67 | 30 | 27 | 32 | 35 | - |
Arcadia | 34.2 | 475 | 118 | 100 | 69 | 96 | 68 | 95 | 68 | 91 | 67 | 73 | 71 | 30 | 31 | 36 | 38 | - |
Arcata | 41 | 218 | 124.1 | 75 | 61 | 69 | 59 | 68 | 59 | 65 | 58 | 61 | 60 | 11 | 28 | 31 | 33 | 5029 |
Arden | 38.5 | 80 | 121.4 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 67 | 73 | 71 | 35 | 28 | 33 | 35 | - |
Arroyo Grande | 35.1 | 105 | 120.6 | 92 | 66 | 86 | 64 | 84 | 64 | 79 | 62 | 67 | 65 | 18 | 28 | 32 | 35 | - |
Artesia | 33.8 | 50 | 118.1 | 99 | 71 | 91 | 70 | 89 | 70 | 85 | 68 | 73 | 71 | 23 | 33 | 37 | 40 | - |
Arvin | 35.2 | 445 | 118.8 | 106 | 71 | 102 | 69 | 101 | 69 | 98 | 68 | 74 | 72 | 30 | 26 | 29 | 32 | - |
Ash Mtn | 36.5 | 1708 | 118.8 | 105 | 69 | 101 | 68 | 100 | 68 | 97 | 66 | 72 | 70 | 30 | 25 | 31 | 33 | 2703 |
Ashland | 37.7 | 45 | 122.1 | 92 | 66 | 86 | 65 | 85 | 64 | 81 | 62 | 68 | 66 | 24 | 26 | 31 | 34 | 977 |
Atascadero | 35.5 | 837 | 120.7 | 94 | 66 | 89 | 67 | 88 | 67 | 84 | 65 | 70 | 68 | 42 | 25 | 29 | 32 | - |
Atherton | 37.5 | 50 | 122.2 | 90 | 66 | 84 | 64 | 82 | 64 | 78 | 62 | 68 | 66 | 27 | 23 | 29 | 33 | - |
Atwater | 37.3 | 150 | 120.6 | 102 | 72 | 99 | 70 | 98 | 69 | 94 | 67 | 74 | 72 | 38 | 24 | 30 | 34 | - |
Auberry | 37.1 | 2140 | 119.5 | 102 | 69 | 98 | 67 | 97 | 66 | 95 | 64 | 71 | 69 | 36 | 21 | 27 | 30 | 3313 |
Auburn | 38.9 | 1292 | 121.1 | 103 | 69 | 100 | 67 | 99 | 67 | 95 | 66 | 72 | 69 | 33 | 25 | 30 | 33 | 3089 |
Avalon | 33.4 | 25 | 118.3 | 83 | 64 | 75 | 62 | 73 | 62 | 69 | 60 | 68 | 66 | 11 | 37 | 41 | 44 | 2204 |
Avenal | 36 | 550 | 120.1 | 103 | 70 | 98 | 70 | 97 | 70 | 93 | 69 | 73 | 72 | 34 | 23 | 28 | 31 | - |
Avocado Heights | 34.2 | 550 | 118 | 101 | 69 | 97 | 68 | 95 | 68 | 91 | 68 | 74 | 72 | 30 | 28 | 32 | 35 | 741 |
Azusa | 34.1 | 605 | 118.2 | 101 | 70 | 97 | 69 | 95 | 69 | 91 | 68 | 74 | 72 | 36 | 31 | 36 | 38 | - |
Baker | 35.3 | 940 | 116.1 | 115 | 73 | 112 | 72 | 111 | 72 | 108 | 70 | 77 | 75 | 29 | 23 | 28 | 31 | - |
Bakersfield AP | 35.4 | 475 | 119.1 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 34 | 26 | 31 | 35 | 2185 |
Balch PH | 36.9 | 1720 | 116.0 | 100 | 67 | 97 | 66 | 96 | 66 | 93 | 64 | 71 | 69 | 26 | 26 | 31 | 34 | - |
Baldwin Park | 34 | 394 | 118 | 100 | 69 | 96 | 69 | 94 | 69 | 90 | 68 | 73 | 72 | 32 | 31 | 36 | 38 | - |
Banning | 33.9 | 2349 | 116.9 | 104 | 69 | 100 | 68 | 99 | 68 | 96 | 67 | 73 | 71 | 34 | 20 | 26 | 30 | - |
Barrett Dam | 32.7 | 1623 | 116.7 | 103 | 69 | 97 | 68 | 96 | 68 | 92 | 67 | 73 | 71 | 35 | 22 | 26 | 28 | 2656 |
Barstow | 34.9 | 2162 | 117 | 107 | 69 | 104 | 69 | 103 | 69 | 100 | 67 | 74 | 72 | 35 | 16 | 23 | 27 | 2580 |
Baywood-Los Osos | 35.3 | 100 | - | 88 | 65 | 82 | 64 | 80 | 64 | 76 | 62 | 67 | 65 | 14 | 31 | 36 | 38 | - |
Beale AFB | 39.1 | 113 | 121.4 | 105 | 71 | 102 | 70 | 101 | 70 | 97 | 68 | 74 | 72 | 34 | 25 | 28 | 30 | 2835 |
Beaumont | 33.9 | 2605 | 117 | 103 | 68 | 99 | 67 | 98 | 67 | 95 | 66 | 72 | 70 | 38 | 22 | 27 | 30 | 2628 |
Bell | 33.9 | 143 | 118.2 | 97 | 70 | 91 | 69 | 89 | 69 | 85 | 67 | 72 | 70 | 22 | 33 | 38 | 41 | - |
Bell Gardens | 33.9 | 160 | 118.2 | 97 | 70 | 91 | 69 | 87 | 67 | 85 | 67 | 72 | 70 | 22 | 32 | 37 | 40 | - |
Bellflower | 33.8 | 73 | 118.1 | 98 | 70 | 91 | 69 | 89 | 69 | 85 | 67 | 72 | 70 | 21 | 32 | 37 | 40 | - |
Belmont | 37.5 | 33 | 122.3 | 90 | 66 | 84 | 64 | 82 | 64 | 78 | 62 | 68 | 66 | 24 | 29 | 34 | 36 | - |
Ben Lomond | 37.1 | 450 | 122.1 | 92 | 67 | 85 | 66 | 83 | 65 | 79 | 63 | 69 | 67 | 30 | 25 | 30 | 33 | - |
Benicia | 38.1 | 55 | 122.1 | 99 | 69 | 93 | 67 | 91 | 67 | 87 | 65 | 70 | 68 | 30 | 28 | 33 | 36 | |
Berkeley | 37.9 | 345 | 122.3 | 90 | 64 | 83 | 63 | 81 | 63 | 76 | 61 | 66 | 64 | 16 | 33 | 37 | 40 | 2950 |
Berryessa Lake | 38.6 | 480 | 122.1 | 102 | 70 | 98 | 69 | 96 | 69 | 92 | 67 | 72 | 70 | 35 | 26 | 31 | 34 | - |
Beverly Hills | 34.1 | 268 | 118.2 | 94 | 69 | 88 | 68 | 87 | 68 | 83 | 66 | 71 | 69 | 20 | 39 | 43 | 46 | - |
Big Bar RS | 40.8 | 1260 | 121.8 | 102 | 68 | 98 | 67 | 97 | 67 | 93 | 65 | 70 | 68 | 46 | 19 | 25 | 28 | - |
Big Bear Lake | 34.2 | 6745 | 116.9 | 87 | 59 | 83 | 58 | 82 | 58 | 79 | 56 | 64 | 62 | 32 | -3 | 3 | 7 | 6850 |
Bishop AP | 37.4 | 4108 | 118.4 | 103 | 61 | 100 | 60 | 99 | 60 | 97 | 58 | 65 | 63 | 40 | 5 | 12 | 16 | 4313 |
Blackhawk | 37.7 | 10 | 121.9 | 88 | 65 | 82 | 64 | 80 | 64 | 76 | 62 | 66 | 64 | 21 | 35 | 38 | 40 | 977 |
Blackwells Corner | 35.6 | 644 | 119.9 | 99 | 68 | 94 | 66 | 93 | 66 | 89 | 65 | 71 | 69 | 31 | 23 | 28 | 32 | - |
Bloomington | 34 | 980 | 117.4 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 69 | 75 | 73 | 34 | 30 | 35 | 38 | - |
Blue Canyon AP | 39.3 | 5280 | 120.7 | 88 | 60 | 85 | 59 | 84 | 59 | 81 | 57 | 64 | 62 | 20 | 13 | 20 | 24 | 5704 |
Blythe AP | 33.6 | 395 | 114.7 | 115 | 74 | 112 | 73 | 111 | 73 | 108 | 71 | 80 | 78 | 27 | 28 | 33 | 36 | 1219 |
Blythe CO | 33.6 | 268 | 114.6 | 115 | 74 | 112 | 73 | 111 | 73 | 108 | 71 | 80 | 78 | 27 | 24 | 29 | 32 | 1312 |
Boca | 39.4 | 5575 | 120.1 | 92 | 58 | 89 | 57 | 88 | 57 | 84 | 55 | 62 | 60 | 46 | -18 | -13 | -10 | 8340 |
Bodie | 38.2 | 8370 | 119 | 83 | 50 | 80 | 49 | 79 | 49 | 76 | 48 | 55 | 53 | 42 | -21 | -16 | -13 | - |
Bonadella Ranchos – Madera Rancho | 36.8 | 270 | 119.9 | 105 | 72 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 40 | 29 | 32 | 1273 | |
Bonita | 32.7 | 105 | 117 | 91 | 69 | 82 | 67 | 81 | 66 | 78 | 64 | 70 | 68 | 20 | 28 | 32 | 44 | 1864 |
Boron AFS | 35.1 | 3015 | 117.6 | 106 | 70 | 103 | 69 | 102 | 69 | 98 | 68 | 73 | 71 | 35 | 18 | 23 | 26 | 3000 |
Borrego Desert PK | 33.2 | 805 | 116.4 | 112 | 76 | 107 | 74 | 105 | 74 | 101 | 72 | 79 | 77 | 36 | 25 | 30 | 33 | - |
Bostonia | 32.8 | 600 | 116.9 | 96 | 70 | 91 | 69 | 88 | 69 | 81 | 67 | 72 | 70 | 30 | 29 | 34 | 36 | - |
Boulder Creek | 37.2 | 493 | 122.1 | 92 | 67 | 85 | 65 | 83 | 65 | 79 | 63 | 69 | 67 | 30 | 25 | 30 | 33 | 1120 |
Bowman Dam | 39.4 | 5347 | 120.7 | 89 | 59 | 86 | 57 | 85 | 57 | 82 | 55 | 63 | 60 | 26 | 9 | 17 | 22 | 5964 |
Boyes Hot Sprgs | 38.2 | 300 | 122.5 | 100 | 70 | 95 | 69 | 93 | 69 | 89 | 67 | 72 | 70 | 40 | 22 | 28 | 31 | 1289 |
Brannan Island | 38.1 | 30 | 121.7 | 100 | 69 | 95 | 68 | 93 | 68 | 89 | 67 | 72 | 70 | 10 | 24 | 28 | 31 | - |
Brawley 2 SW | 33 | -100 | 115.6 | 113 | 74 | 110 | 73 | 109 | 73 | 105 | 73 | 81 | 79 | 32 | 25 | 30 | 33 | 1204 |
Brea Dam | 33.9 | 275 | 117.9 | 100 | 69 | 94 | 68 | 92 | 68 | 86 | 66 | 73 | 71 | 29 | 30 | 34 | 37 | - |
Brentwood | 37.9 | 71 | 121.7 | 102 | 70 | 97 | 68 | 95 | 67 | 89 | 65 | 71 | 68 | 34 | 27 | 32 | 35 | - |
Bridgeport | 38.2 | 6470 | 119.2 | 89 | 56 | 86 | 54 | 85 | 54 | 82 | 53 | 60 | 57 | 41 | -20 | -15 | -12 | - |
Broderick-Bryte | 38.6 | 20 | 121.5 | 104 | 71 | 100 | 69 | 98 | 69 | 94 | 67 | 72 | 71 | 36 | 25 | 31 | 35 | - |
Brooks Ranch | 38.8 | 294 | 122.2 | 104 | 71 | 99 | 70 | 97 | 70 | 93 | 68 | 73 | 71 | 35 | 19 | 25 | 28 | 2968 |
Buena Park | 33.9 | 75 | 118 | 98 | 69 | 92 | 68 | 90 | 68 | 85 | 67 | 72 | 70 | 25 | 31 | 35 | 38 | - |
Burbank AP | 34.2 | 699 | 118.4 | 101 | 70 | 96 | 68 | 94 | 68 | 90 | 67 | 72 | 70 | 28 | 29 | 34 | 36 | 1701 |
Burbank Vly Pump | 34.2 | 655 | 118.4 | 101 | 69 | 96 | 68 | 94 | 68 | 90 | 66 | 72 | 70 | 28 | 29 | 34 | 36 | 1678 |
Burlingame | 37.6 | 10 | 122.4 | 88 | 67 | 82 | 64 | 80 | 64 | 76 | 63 | 68 | 65 | 20 | 30 | 35 | 37 | - |
Burney | 40.9 | 3127 | 121.7 | 95 | 64 | 92 | 63 | 91 | 63 | 88 | 61 | 67 | 65 | 42 | 0 | 5 | 12 | 6404 |
Butler Valley (Korbel) | 40.7 | 420 | 123.9 | 91 | 66 | 86 | 64 | 85 | 64 | 81 | 62 | 67 | 65 | 22 | 20 | 26 | 29 | - |
Buttonwillow | 35.4 | 269 | 119.5 | 103 | 71 | 99 | 70 | 98 | 70 | 95 | 68 | 74 | 72 | 36 | 20 | 26 | 29 | 2621 |
Cabrillo NM | 32.7 | 410 | 117.2 | 89 | 69 | 84 | 68 | 83 | 68 | 80 | 67 | 71 | 69 | 12 | 39 | 43 | 45 | - |
Cachuma Lake | 34.6 | 781 | 120 | 97 | 69 | 92 | 67 | 91 | 67 | 87 | 65 | 70 | 68 | 19 | 26 | 31 | 34 | - |
Calabasas | 34.2 | 1100 | 118.6 | 102 | 71 | 98 | 70 | 97 | 70 | 93 | 69 | 73 | 71 | 26 | 26 | 30 | 33 | 2348 |
Calaveras Big Trees | 38.3 | 4696 | 120.3 | 92 | 61 | 88 | 60 | 87 | 60 | 84 | 58 | 64 | 62 | 33 | 11 | 18 | 23 | 5848 |
Calexico | 32.7 | 12 | 115.5 | 114 | 74 | 110 | 73 | 109 | 73 | 106 | 71 | 81 | 79 | 28 | 26 | 31 | 34 | - |
California City | 35.1 | 2400 | 118 | 107 | 69 | 104 | 68 | 103 | 68 | 99 | 66 | 72 | 70 | 33 | 10 | 17 | 22 | 2572 |
Callahan | 41.3 | 3185 | 122.8 | 97 | 63 | 93 | 62 | 92 | 62 | 88 | 60 | 66 | 64 | 35 | 7 | 15 | 20 | - |
Calwa | 36.8 | 330 | 119.8 | 105 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 34 | 23 | 27 | 29 | - |
Camarillo | 34.2 | 147 | 119.2 | 91 | 69 | 84 | 68 | 82 | 68 | 78 | 67 | 71 | 69 | 22 | 28 | 32 | 35 | |
Cambria AFS | 35.5 | 690 | 121.1 | 78 | 62 | 72 | 61 | 70 | 61 | 66 | 59 | 64 | 62 | 16 | 30 | 35 | 38 | 3646 |
Cameron Park | 38.6 | 1800 | 121 | 101 | 67 | 98 | 66 | 97 | 66 | 93 | 65 | 70 | 68 | 42 | 20 | 26 | 29 | 2235 |
Camp Pardee | 38.2 | 658 | 120.9 | 106 | 71 | 103 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 36 | 27 | 32 | 35 | 2812 |
Camp Pendleton | 33.4 | 50 | 117.4 | 88 | 69 | 85 | 68 | 84 | 68 | 80 | 67 | 71 | 69 | 12 | 34 | 38 | 40 | - |
Camp Roberts | 35.8 | 765 | 120.8 | 106 | 72 | 101 | 71 | 99 | 71 | 95 | 69 | 74 | 72 | 45 | 16 | 24 | 27 | 2890 |
Campbell | 37.3 | 195 | 121.8 | 93 | 69 | 88 | 66 | 87 | 66 | 83 | 65 | 71 | 68 | 30 | 28 | 33 | 36 | - |
Campo | 32.6 | 2630 | 116.5 | 101 | 67 | 95 | 66 | 94 | 66 | 90 | 66 | 71 | 69 | 41 | 16 | 23 | 27 | 3303 |
Canoga Park | 34.2 | 790 | 118.6 | 104 | 71 | 99 | 70 | 97 | 70 | 93 | 69 | 74 | 72 | 38 | 25 | 30 | 33 | 1884 |
Cantil | 35.3 | 2010 | 118 | 111 | 71 | 107 | 71 | 106 | 71 | 103 | 70 | 74 | 73 | 32 | 12 | 19 | 24 | - |
Canyon Dam | 40.1 | 4555 | 121.1 | 93 | 60 | 90 | 59 | 89 | 59 | 85 | 57 | 64 | 62 | 39 | 1 | 6 | 13 | 6834 |
Canyon Lake | 33.8 | 1500 | 117.3 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 68 | 74 | 72 | 39 | 22 | 27 | 30 | - |
Capitola | 37 | 64 | 122 | 94 | 67 | 88 | 66 | 86 | 65 | 81 | 63 | 69 | 67 | 24 | 27 | 32 | 35 | - |
Cardiff-by-the-Sea | 33 | 80 | 117.3 | 87 | 68 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 12 | 35 | 39 | 41 | - |
Carlsbad | 33.2 | 44 | 117.4 | 87 | 68 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 10 | 34 | 38 | 40 | - |
Carmel Valley | 36.5 | 425 | 121.7 | 94 | 68 | 88 | 66 | 86 | 66 | 80 | 65 | 69 | 67 | 20 | 25 | 30 | 33 | - |
Carmel-by-the-Sea | 36.5 | 20 | 121.9 | 87 | 65 | 78 | 62 | 76 | 62 | 71 | 61 | 66 | 63 | 20 | 30 | 35 | 38 | 968 |
Carmichael | 38.6 | 100 | 121.5 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 68 | 73 | 71 | 35 | 25 | 35 | 37 | 1290 |
Carpinteria | 34.4 | 385 | 119.5 | 90 | 69 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 15 | 30 | 34 | 37 | - |
Carson | 33.8 | 60 | 118.3 | 96 | 69 | 88 | 68 | 86 | 68 | 82 | 66 | 71 | 69 | 19 | 33 | 38 | 40 | - |
Casa de Oro-Mount Helix | 32.7 | 530 | 117.0 | 96 | 71 | 88 | 69 | 87 | 69 | 84 | 67 | 72 | 70 | 19 | 34 | 38 | 41 | 404 |
Castle AFB | 37.4 | 188 | 120.6 | 105 | 71 | 101 | 70 | 100 | 70 | 96 | 69 | 73 | 71 | 33 | 24 | 28 | 31 | 2590 |
Castro Valley | 37.6 | 177 | 122.2 | 93 | 67 | 87 | 67 | 85 | 67 | 80 | 65 | 69 | 68 | 25 | 24 | 29 | 32 | - |
Castroville | 36.8 | 20 | 121.8 | 86 | 66 | 77 | 63 | 75 | 63 | 70 | 61 | 67 | 64 | 18 | 32 | 37 | 40 | 1151 |
Cathedral City | 33.8 | 400 | 116.5 | 117 | 74 | 113 | 73 | 112 | 73 | 109 | 72 | 79 | 78 | 33 | 26 | 31 | 34 | 374 |
Catheys Valley | 37.4 | 1000 | 120.1 | 102 | 69 | 99 | 68 | 98 | 68 | 94 | 67 | 72 | 70 | 38 | 21 | 27 | 30 | - |
Cecilville | 41.1 | 3000 | 123.1 | 95 | 63 | 89 | 62 | 88 | 61 | 84 | 59 | 65 | 63 | 44 | 13 | 20 | 24 | - |
Cedarville | 41.5 | 4670 | 120.2 | 97 | 61 | 94 | 60 | 93 | 60 | 89 | 58 | 65 | 63 | 35 | 1 | 6 | 13 | 6304 |
Centerville PH | 39.8 | 522 | 121.7 | 105 | 70 | 100 | 68 | 99 | 68 | 96 | 67 | 72 | 70 | 40 | 25 | 30 | 33 | 2895 |
Ceres | 37.6 | 90 | 121 | 101 | 72 | 96 | 70 | 94 | 69 | 90 | 67 | 74 | 72 | 36 | 24 | 30 | 34 | - |
Cerritos | 33.9 | 34 | 118.1 | 99 | 71 | 92 | 69 | 90 | 69 | 85 | 68 | 73 | 71 | 23 | 33 | 38 | 40 | - |
Charter Oak | 34.1 | 600 | 117.9 | 101 | 70 | 97 | 69 | 95 | 69 | 91 | 68 | 74 | 72 | 34 | 29 | 34 | 36 | - |
Chatsworth | 34.2 | 964 | 118.6 | 98 | 69 | 93 | 68 | 91 | 68 | 87 | 66 | 72 | 70 | 38 | 26 | 31 | 34 | 664 |
Cherry Valley Dam | 38 | 4765 | 119.9 | 96 | 62 | 92 | 61 | 91 | 61 | 88 | 59 | 65 | 63 | 32 | 9 | 16 | 21 | - |
Cherryland | 37.5 | 100 | 122.1 | 93 | 67 | 86 | 66 | 84 | 66 | 79 | 64 | 69 | 67 | 24 | 26 | 31 | 37 | - |
Chester | 40.3 | 4525 | 121.2 | 94 | 62 | 91 | 61 | 90 | 61 | 86 | 59 | 65 | 63 | 33 | -3 | 2 | 8 | - |
Chico Exp Sta | 39.7 | 205 | 121.8 | 105 | 70 | 102 | 69 | 100 | 69 | 96 | 68 | 72 | 71 | 37 | 22 | 27 | 30 | 2878 |
China Lake | 35.7 | 2220 | 117.7 | 112 | 70 | 108 | 68 | 107 | 68 | 104 | 68 | 74 | 72 | 33 | 15 | 22 | 25 | 2560 |
Chino | 34 | 714 | 117.7 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 68 | 74 | 72 | 35 | 27 | 32 | 35 | - |
Chino Hills | 34.1 | 800 | 117.7 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 68 | 74 | 72 | 35 | 27 | 32 | 35 | 800 |
Chowchilla | 37 | 200 | 120.3 | 104 | 72 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 38 | 22 | 28 | 31 | 1250 |
Chula Vista | 32.6 | 9 | 117.1 | 90 | 70 | 84 | 68 | 83 | 68 | 79 | 66 | 71 | 69 | 9 | 33 | 38 | 40 | 2072 |
Citrus Heights | 38.7 | 138 | 121.5 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 74 | 72 | 36 | 24 | 26 | 29 | - |
Claremont | 34.1 | 1201 | 117.8 | 101 | 69 | 97 | 68 | 95 | 68 | 91 | 66 | 73 | 71 | 34 | 29 | 34 | 36 | 2049 |
Clarksburg | 38.4 | 14 | 121.5 | 102 | 70 | 97 | 69 | 95 | 69 | 91 | 67 | 72 | 70 | 35 | 24 | 29 | 32 | 2971 |
Clayton | 38 | 60 | 121.9 | 102 | 70 | 97 | 68 | 95 | 67 | 89 | 65 | 71 | 68 | 34 | 27 | 32 | 35 | - |
Clearlake Highlands | 39 | 1360 | 122.7 | 101 | 69 | 97 | 68 | 95 | 67 | 89 | 65 | 71 | 69 | 36 | 15 | 22 | 26 | - |
Cloverdale | 38.8 | 320 | 123 | 102 | 70 | 97 | 69 | 95 | 68 | 89 | 66 | 72 | 70 | 37 | 26 | 31 | 34 | 2763 |
Clovis | 36.8 | 404 | 119.7 | 105 | 72 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 36 | 22 | 28 | 32 | - |
Coachella | 33.7 | -76 | 116.2 | 114 | 74 | 110 | 73 | 109 | 73 | 106 | 73 | 80 | 79 | 28 | 25 | 30 | 34 | - |
Coalinga | 36.2 | 671 | 120.4 | 103 | 70 | 98 | 70 | 97 | 70 | 93 | 69 | 73 | 72 | 34 | 23 | 28 | 31 | 2592 |
Colfax | 39.1 | 2418 | 121 | 100 | 66 | 97 | 65 | 96 | 65 | 92 | 63 | 69 | 67 | 29 | 22 | 28 | 31 | 3424 |
Colton | 34.1 | 978 | 117.3 | 105 | 70 | 102 | 68 | 101 | 68 | 97 | 67 | 74 | 72 | 35 | 28 | 33 | 36 | - |
Colusa | 39.2 | 60 | 122 | 103 | 72 | 100 | 70 | 98 | 70 | 94 | 68 | 74 | 71 | 36 | 23 | 29 | 31 | 2793 |
Commerce | 33.9 | 175 | 118.2 | 98 | 69 | 92 | 68 | 90 | 68 | 86 | 67 | 72 | 70 | 23 | 33 | 37 | 39 | - |
Compton | 33.9 | 71 | 118.2 | 97 | 69 | 90 | 68 | 88 | 68 | 83 | 67 | 72 | 70 | 21 | 33 | 37 | 39 | 1606 |
Concord | 38 | 195 | 112 | 102 | 70 | 97 | 68 | 95 | 67 | 89 | 65 | 71 | 68 | 34 | 27 | 32 | 35 | 3035 |
Corcoran | 36.1 | 200 | 119.7 | 106 | 72 | 102 | 71 | 101 | 71 | 98 | 70 | 74 | 73 | 36 | 22 | 28 | 31 | 2666 |
Corning | 39.9 | 487 | 122.2 | 106 | 71 | 103 | 70 | 102 | 69 | 98 | 67 | 73 | 71 | 33 | 23 | 28 | 31 | 1330 |
Corona | 33.9 | 710 | 117.6 | 104 | 70 | 100 | 69 | 98 | 69 | 92 | 67 | 74 | 72 | 35 | 26 | 31 | 34 | 1794 |
Coronado | 32.7 | 20 | 117.2 | 89 | 69 | 82 | 67 | 80 | 67 | 76 | 65 | 70 | 68 | 10 | 36 | 39 | 41 | 1500 |
Corte Madera | 37.9 | 55 | 122.5 | 97 | 68 | 91 | 66 | 89 | 66 | 84 | 64 | 69 | 68 | 34 | 28 | 33 | 35 | - |
Costa Mesa | 33.7 | 100 | 117.9 | 88 | 68 | 81 | 66 | 79 | 66 | 73 | 65 | 70 | 68 | 16 | 31 | 36 | 38 | 1482 |
Cotati | 38.3 | 100 | 122.7 | 99 | 69 | 94 | 68 | 93 | 68 | 89 | 66 | 71 | 69 | 32 | 24 | 28 | 30 | 1205 |
Country Club | 37.8 | 600 | 121.3 | 102 | 69 | 97 | 68 | 96 | 68 | 92 | 66 | 72 | 70 | 30 | 68 | 28 | 31 | 977 |
Covelo | 39.8 | 1385 | 123.3 | 99 | 67 | 93 | 65 | 91 | 65 | 87 | 63 | 69 | 67 | 43 | 15 | 22 | 26 | 4179 |
Covina | 34.1 | 575 | 117.9 | 101 | 70 | 97 | 69 | 95 | 69 | 91 | 68 | 74 | 72 | 34 | 29 | 34 | 36 | - |
Crescent City | 41.8 | 40 | 124.2 | 75 | 61 | 69 | 59 | 68 | 59 | 65 | 58 | 61 | 60 | 18 | 28 | 33 | 36 | 4445 |
Crestline | 34.2 | 4900 | 117.3 | 90 | 62 | 86 | 61 | 85 | 61 | 81 | 59 | 66 | 64 | 26 | 13 | 20 | 24 | 3200 |
Crockett | 38 | 9 | 122.2 | 96 | 68 | 90 | 66 | 89 | 66 | 85 | 64 | 70 | 67 | 23 | 28 | 33 | 36 | - |
Crows Landing | 37.4 | 140 | 121.1 | 101 | 70 | 96 | 68 | 94 | 68 | 89 | 66 | 72 | 70 | 33 | 23 | 28 | 31 | 2767 |
Cucamonga | 34.1 | 1450 | 117.6 | 103 | 69 | 99 | 68 | 97 | 67 | 93 | 65 | 73 | 71 | 31 | 29 | 34 | 36 | - |
Cudahy | 33.9 | 130 | 118.2 | 98 | 70 | 91 | 69 | 89 | 69 | 85 | 67 | 72 | 70 | 21 | 33 | 37 | 39 | - |
Culver City | 34 | 106 | 118.4 | 96 | 70 | 88 | 69 | 87 | 69 | 83 | 67 | 72 | 70 | 18 | 35 | 40 | 42 | 1515 |
Cupertino | 37.3 | 70 | 122 | 96 | 68 | 88 | 67 | 86 | 66 | 80 | 64 | 70 | 68 | 30 | 28 | 33 | 36 | - |
Cuyama | 34.9 | 2255 | 116.6 | 99 | 68 | 96 | 67 | 94 | 67 | 89 | 66 | 72 | 70 | 42 | 13 | 20 | 24 | - |
Cuyamaca | 33 | 4650 | 116.6 | 92 | 64 | 85 | 62 | 84 | 61 | 81 | 59 | 67 | 65 | 29 | 11 | 18 | 23 | 4848 |
Cypress | 33.8 | 75 | 118 | 98 | 70 | 92 | 69 | 90 | 69 | 85 | 67 | 72 | 70 | 24 | 31 | 35 | 38 | |
Daggett AP | 34.9 | 1915 | 116.8 | 109 | 68 | 106 | 68 | 105 | 68 | 102 | 66 | 73 | 72 | 33 | 21 | 26 | 29 | 2203 |
Daly City | 37.6 | 410 | 122.5 | 84 | 65 | 78 | 62 | 77 | 62 | 73 | 61 | 66 | 63 | 16 | 34 | 37 | 39 | - |
Dana Point | 33.5 | 100 | 117.7 | 91 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 13 | 30 | 33 | 36 | 600 |
Danville | 37.8 | 368 | 122 | 102 | 69 | 97 | 68 | 96 | 68 | 92 | 66 | 72 | 70 | 30 | 23 | 28 | 31 | 977 |
Davis | 38.5 | 60 | 121.8 | 103 | 72 | 99 | 70 | 97 | 70 | 93 | 68 | 74 | 71 | 41 | 24 | 30 | 34 | 2844 |
De Sabla | 39.9 | 2713 | 121.6 | 97 | 66 | 94 | 64 | 92 | 64 | 88 | 62 | 68 | 66 | 35 | 18 | 24 | 27 | 4237 |
Death Valley | 36.5 | -194 | 116.9 | 121 | 77 | 118 | 76 | 117 | 76 | 114 | 74 | 81 | 79 | 28 | 27 | 33 | 37 | 1147 |
Deep Springs Clg | 37.5 | 5225 | 118 | 98 | 60 | 95 | 59 | 94 | 59 | 92 | 58 | 64 | 62 | 35 | -3 | 2 | 8 | |
Deer Creek PH | 39.3 | 4455 | 120.9 | 93 | 61 | 91 | 60 | 90 | 60 | 87 | 58 | 65 | 63 | 39 | 10 | 17 | 22 | 5863 |
Del Aire | 34 | 100 | 118.4 | 91 | 69 | 84 | 67 | 83 | 67 | 79 | 66 | 71 | 69 | 15 | 37 | 40 | 42 | 383 |
Delano | 35.8 | 323 | 119.3 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 69 | 74 | 72 | 36 | 22 | 25 | 28 | - |
Denair | 37.6 | 137 | 120.8 | 100 | 70 | 95 | 69 | 93 | 69 | 89 | 67 | 72 | 70 | 38 | 22 | 28 | 31 | 2974 |
Desert Hot Springs | 34 | 1060 | 116.5 | 115 | 73 | 111 | 72 | 110 | 72 | 107 | 71 | 78 | 77 | 35 | 24 | 29 | 32 | 400 |
Diamond Bar | 34 | 880 | 117.8 | 101 | 69 | 97 | 68 | 96 | 68 | 92 | 66 | 73 | 71 | 33 | 28 | 33 | 35 | - |
Dinuba | 36.5 | 340 | 119.4 | 104 | 73 | 101 | 70 | 100 | 70 | 96 | 69 | 75 | 73 | 36 | 24 | 30 | 34 | - |
Discovery Bay | 38.1 | 10 | 121.6 | 102 | 70 | 97 | 68 | 95 | 67 | 89 | 65 | 71 | 68 | 34 | 27 | 32 | 35 | - |
Dixon | 38.4 | 100 | 121.9 | 104 | 72 | 99 | 70 | 97 | 70 | 93 | 68 | 74 | 71 | 36 | 24 | 30 | 33 | 2826 |
Dobbins | 39.4 | 1640 | 121.2 | 104 | 70 | 101 | 68 | 100 | 68 | 96 | 67 | 72 | 70 | 31 | 24 | 29 | 32 | - |
Donner Mem Stt Pk | 39.3 | 5937 | 120.3 | 85 | 56 | 82 | 56 | 81 | 56 | 77 | 54 | 60 | 58 | 40 | -3 | 3 | 6 | - |
Donner Summit | 39.4 | 7239 | 120.3 | 80 | 53 | 77 | 53 | 76 | 52 | 72 | 50 | 57 | 55 | 40 | -8 | -1 | 3 | 8290 |
Downey | 33.9 | 110 | 118 | 98 | 71 | 90 | 70 | 88 | 70 | 84 | 68 | 73 | 71 | 21 | 32 | 37 | 39 | - |
Downieville RS | 39.6 | 2895 | 120.8 | 98 | 64 | 95 | 63 | 94 | 63 | 90 | 61 | 68 | 66 | 42 | 13 | 20 | 24 | - |
Doyle | 40 | 4390 | 120.1 | 96 | 63 | 93 | 62 | 92 | 61 | 88 | 59 | 66 | 64 | 42 | 0 | 5 | 12 | - |
Dry Canyon Res | 34.5 | 1455 | 118.5 | 105 | 71 | 100 | 69 | 99 | 69 | 96 | 68 | 74 | 72 | 32 | 24 | 29 | 32 | - |
Duarte | 34.1 | 500 | 118 | 100 | 69 | 96 | 68 | 94 | 68 | 90 | 67 | 73 | 71 | 33 | 31 | 36 | 38 | - |
Dublin | 37.7 | 200 | 121.5 | 99 | 69 | 93 | 67 | 91 | 67 | 86 | 65 | 70 | 68 | 35 | 24 | 29 | 32 | - |
Dudleys | 37.7 | 3000 | 120.1 | 97 | 65 | 94 | 64 | 93 | 64 | 90 | 62 | 68 | 66 | 44 | 10 | 17 | 22 | 4959 |
Duttons Landing | 38.2 | 20 | 122.3 | 96 | 68 | 91 | 66 | 89 | 66 | 84 | 64 | 70 | 68 | 31 | 26 | 31 | 34 | - |
Eagle Mtn | 33.8 | 973 | 115.5 | 113 | 72 | 110 | 71 | 109 | 71 | 105 | 69 | 77 | 75 | 24 | 32 | 37 | 39 | 1138 |
Earlimart | 35.8 | 283 | 119.3 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 69 | 74 | 72 | 36 | 23 | 26 | 29 | 1100 |
East Compton | 34 | 71 | 118.2 | 97 | 69 | 90 | 68 | 88 | 68 | 83 | 67 | 72 | 70 | 21 | 33 | 37 | 39 | 436 |
East Hemet | 33.7 | 1655 | 116.9 | 109 | 70 | 104 | 69 | 103 | 69 | 101 | 67 | 74 | 72 | 40 | 20 | 25 | 28 | - |
East La Mirada | 33.9 | 115 | 118.0 | 99 | 70 | 91 | 69 | 89 | 69 | 85 | 68 | 73 | 71 | 26 | 31 | 36 | 38 | - |
East Los Angeles | 34 | 250 | 118.3 | 99 | 69 | 92 | 68 | 90 | 68 | 86 | 67 | 72 | 70 | 21 | 38 | 41 | 43 | - |
East Palo Alto | 37.5 | 25 | 122.1 | 93 | 66 | 85 | 64 | 83 | 64 | 77 | 62 | 68 | 66 | 25 | 26 | 31 | 34 | 1103 |
East Park Res | 39.4 | 1205 | 122.5 | 101 | 69 | 97 | 68 | 96 | 68 | 92 | 66 | 71 | 69 | 38 | 19 | 25 | 28 | 3455 |
East Pasadena | 34.2 | 864 | 118.1 | 99 | 69 | 94 | 68 | 92 | 68 | 88 | 67 | 73 | 71 | 30 | 32 | 37 | 40 | 452 |
East Porterville | 36.1 | 393 | 119.0 | 106 | 71 | 102 | 70 | 101 | 70 | 97 | 69 | 74 | 72 | 36 | 25 | 30 | 33 | 1129 |
East San Gabriel | 34.1 | 450 | 118.1 | 99 | 70 | 94 | 69 | 92 | 69 | 88 | 68 | 73 | 71 | 30 | 30 | 35 | 37 | 431 |
Edwards AFB | 34.9 | 2316 | 117.9 | 107 | 69 | 104 | 68 | 103 | 68 | 99 | 66 | 72 | 70 | 35 | 10 | 17 | 22 | 3123 |
El Cajon | 32.7 | 525 | 117 | 96 | 70 | 91 | 69 | 90 | 69 | 87 | 67 | 72 | 70 | 30 | 29 | 34 | 36 | - |
El Capitan Dam | 32.9 | 600 | 116.8 | 105 | 71 | 98 | 70 | 97 | 70 | 93 | 68 | 74 | 72 | 35 | 29 | 34 | 36 | 1533 |
El Centro | 32.8 | -30 | 115.6 | 115 | 74 | 111 | 73 | 110 | 73 | 107 | 73 | 81 | 79 | 34 | 26 | 35 | 38 | 1212 |
El Cerrito | 37.8 | 70 | 122.3 | 91 | 66 | 84 | 64 | 81 | 64 | 75 | 62 | 68 | 65 | 17 | 30 | 35 | 38 | - |
El Dorado Hills | 38.6 | 673 | 121.1 | 103 | 70 | 100 | 69 | 98 | 69 | 94 | 67 | 72 | 71 | 36 | 24 | 30 | 34 | - |
El Mirage | 34.6 | 2910 | 117.6 | 105 | 69 | 101 | 68 | 100 | 68 | 97 | 66 | 72 | 70 | 31 | 9 | 16 | 21 | - |
El Monte | 34.1 | 271 | 118 | 101 | 71 | 97 | 70 | 95 | 70 | 91 | 68 | 73 | 71 | 30 | 31 | 36 | 39 | - |
El Paso de Robles | 35.6 | 721 | 120.7 | 102 | 65 | 95 | 65 | 94 | 65 | 90 | 65 | 69 | 67 | 44 | 16 | 20 | 23 | 1768 |
El Rio | 34.3 | 50 | 119.2 | 95 | 69 | 88 | 68 | 86 | 68 | 82 | 66 | 71 | 69 | 20 | 30 | 34 | 37 | - |
El Segundo | 33.9 | 105 | 118.4 | 91 | 69 | 84 | 68 | 83 | 68 | 79 | 66 | 71 | 69 | 14 | 37 | 40 | 42 | - |
El Sobrante | 37.9 | 55 | 122.3 | 91 | 66 | 87 | 65 | 86 | 65 | 82 | 64 | 69 | 67 | 25 | 30 | 35 | 38 | 823 |
El Toro MCAS | 33.7 | 380 | 117.7 | 96 | 69 | 89 | 69 | 87 | 69 | 82 | 68 | 73 | 71 | 26 | 34 | 38 | 41 | 1591 |
El Toro Station | 33.7 | 380 | 117.7 | 96 | 69 | 89 | 69 | 87 | 69 | 82 | 68 | 73 | 71 | 26 | 34 | 38 | 41 | 560 |
Electra PH | 38.3 | 715 | 120.7 | 106 | 70 | 102 | 69 | 101 | 69 | 98 | 68 | 73 | 71 | 41 | 23 | 28 | 31 | 2858 |
Elk Grove | 38.4 | 50 | 121.4 | 104 | 71 | 100 | 69 | 98 | 69 | 94 | 68 | 73 | 71 | 35 | 29 | 34 | 36 | 1150 |
Elk Valley | 42 | 1705 | 123.7 | 96 | 65 | 90 | 63 | 88 | 63 | 84 | 61 | 67 | 65 | 39 | 16 | 23 | 27 | 5404 |
Elsinore | 33.7 | 1285 | 117.3 | 105 | 71 | 101 | 70 | 100 | 70 | 98 | 69 | 74 | 72 | 39 | 22 | 26 | 29 | 2128 |
Encinitas | 33 | 50 | 117.3 | 87 | 68 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 10 | 35 | 39 | 41 | - |
Encino | 34.2 | 750 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 27 | 28 | 33 | 36 | 664 |
Enterprise | 40.6 | 470 | 122.3 | 107 | 69 | 103 | 68 | 101 | 68 | 97 | 67 | 72 | 70 | 29 | 26 | 31 | 34 | - |
Escondido | 33.1 | 660 | 117.1 | 97 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 29 | 26 | 31 | 34 | 2005 |
Eureka | 40.8 | 43 | 124.2 | 75 | 61 | 69 | 59 | 68 | 59 | 65 | 58 | 61 | 60 | 11 | 30 | 35 | 38 | 4679 |
Exeter | 36.3 | 350 | 119.1 | 104 | 72 | 101 | 71 | 100 | 71 | 97 | 69 | 74 | 72 | 39 | 24 | 29 | 32 | 1236 |
Fair Oaks | 38.7 | 50 | 121.3 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 69 | 72 | 71 | 36 | 23 | 29 | 33 | - |
Fairfax | 38 | 110 | 122.6 | 96 | 68 | 90 | 66 | 88 | 65 | 83 | 63 | 71 | 68 | 34 | 26 | 31 | 34 | - |
Fairfield FS | 38.3 | 38 | 122 | 103 | 69 | 98 | 68 | 96 | 68 | 91 | 66 | 73 | 71 | 34 | 24 | 30 | 33 | 2686 |
Fairmont | 34.7 | 3060 | 118.4 | 100 | 67 | 96 | 66 | 95 | 66 | 92 | 65 | 71 | 69 | 22 | 22 | 28 | 31 | 3330 |
Fairview | 35.9 | 3519 | 118.5 | 97 | 67 | 94 | 66 | 93 | 66 | 90 | 64 | 70 | 68 | 43 | 11 | 18 | 23 | - |
Fallbrook | 33.6 | 660 | 117.3 | 94 | 68 | 89 | 67 | 88 | 67 | 85 | 66 | 71 | 69 | 29 | 26 | 31 | 34 | 2077 |
Farmersville | 36.3 | 350 | 119.2 | 104 | 72 | 101 | 72 | 100 | 71 | 97 | 69 | 74 | 72 | 39 | 24 | 29 | 32 | 1236 |
Felton | 37 | 100 | 122.1 | 94 | 68 | 88 | 66 | 86 | 66 | 81 | 64 | 69 | 67 | 28 | 27 | 32 | 35 | 1097 |
Ferndale | 40.5 | 1445 | 124.3 | 76 | 57 | 66 | 56 | 65 | 56 | 62 | 54 | 59 | 57 | 12 | 28 | 33 | 35 | - |
Fillmore | 34.4 | 435 | 118.9 | 100 | 70 | 94 | 69 | 92 | 69 | 87 | 67 | 73 | 71 | 30 | 28 | 32 | 35 | - |
Five Points | 36.4 | 285 | 120.2 | 103 | 71 | 99 | 70 | 97 | 70 | 93 | 68 | 73 | 71 | 36 | 21 | 27 | 30 | - |
Fleming Fish & Game | 40.4 | 4000 | 120.3 | 96 | 62 | 93 | 61 | 92 | 61 | 88 | 59 | 66 | 64 | 40 | -3 | 2 | 8 | - |
Florence-Graham | 34 | 175 | 118.3 | 98 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 19 | 35 | 40 | 43 | - |
Florin | 38.5 | 100 | 121.4 | 104 | 71 | 100 | 69 | 98 | 69 | 94 | 68 | 73 | 71 | 35 | 29 | 34 | 36 | - |
Folsom Dam | 38.7 | 350 | 121.2 | 104 | 70 | 101 | 69 | 99 | 69 | 95 | 67 | 72 | 71 | 36 | 25 | 31 | 35 | - |
Fontana | 34.1 | 1090 | 117.4 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 67 | 74 | 72 | 33 | 30 | 35 | 38 | 1530 |
Foothill Farms | 38.6 | 90 | 121.3 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 36 | 24 | 30 | 34 | - |
Forest Glen | 40.4 | 2340 | 123.3 | 96 | 65 | 92 | 64 | 91 | 64 | 88 | 62 | 67 | 65 | 42 | 12 | 19 | 24 | - |
Fort Baker | 37.8 | 15 | 122.5 | 87 | 66 | 81 | 65 | 79 | 65 | 73 | 65 | 67 | 65 | 12 | 33 | 38 | 40 | 3080 |
Fort Bidwell | 41.9 | 4498 | 120.1 | 93 | 60 | 90 | 59 | 89 | 59 | 85 | 57 | 64 | 62 | 38 | -2 | 3 | 10 | 6381 |
Fort Bragg | 39.5 | 80 | 123.8 | 75 | 60 | 67 | 59 | 66 | 59 | 62 | 58 | 62 | 61 | 15 | 29 | 34 | 37 | 4424 |
Fort Jones RS | 41.6 | 2725 | 122.9 | 98 | 64 | 93 | 63 | 92 | 63 | 88 | 61 | 67 | 65 | 44 | 5 | 13 | 18 | 5590 |
Fort MacArthur | 33.7 | 200 | 118.3 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 13 | 35 | 40 | 42 | 1819 |
Fort Ord | 36.7 | 134 | 121.8 | 86 | 65 | 77 | 63 | 75 | 62 | 70 | 60 | 67 | 64 | 18 | 24 | 29 | 32 | 3818 |
Fort Ross | 38.5 | 116 | 123.3 | 79 | 63 | 74 | 62 | 71 | 61 | 65 | 59 | 64 | 62 | 19 | 30 | 35 | 37 | 4127 |
Fortuna | 40.6 | 100 | 124.2 | 75 | 61 | 69 | 59 | 68 | 59 | 65 | 58 | 61 | 60 | 11 | 30 | 35 | 38 | 2000 |
Foster City | 37.5 | 20 | 122.7 | 92 | 67 | 84 | 65 | 82 | 65 | 76 | 63 | 68 | 66 | 22 | 29 | 34 | 36 | - |
Fountain Valley | 33.7 | 60 | 118 | 97 | 70 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 18 | 33 | 38 | 40 | - |
Freedom | 37 | 1495 | 121.8 | 89 | 67 | 85 | 64 | 83 | 64 | 79 | 62 | 68 | 65 | 22 | 27 | 32 | 34 | - |
Fremont | 37.5 | 56 | 122 | 94 | 67 | 88 | 65 | 86 | 65 | 81 | 63 | 69 | 67 | 24 | 25 | 30 | 33 | - |
Fresno AP | 36.8 | 328 | 119.7 | 104 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 34 | 24 | 28 | 30 | 2650 |
Friant Gov Camp | 37 | 410 | 119.7 | 106 | 72 | 103 | 70 | 102 | 70 | 100 | 68 | 74 | 72 | 40 | 23 | 28 | 31 | 2768 |
Fullerton | 33.9 | 340 | 117.9 | 100 | 70 | 94 | 69 | 92 | 69 | 87 | 68 | 73 | 71 | 26 | 30 | 35 | 37 | - |
Galt | 38.2 | 40 | 121.3 | 101 | 70 | 97 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 38 | 23 | 28 | 31 | 1240 |
Garden Acres | 38 | 20 | 121.3 | 103 | 71 | 98 | 69 | 97 | 69 | 93 | 67 | 73 | 71 | 35 | 24 | 28 | 30 | 1334 |
Garden Grove | 33.6 | 85 | 117.9 | 98 | 70 | 91 | 68 | 89 | 68 | 84 | 67 | 72 | 70 | 23 | 31 | 36 | 38 | - |
Gardena | 33.9 | 40 | 118.3 | 92 | 69 | 85 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 18 | 32 | 37 | 39 | - |
George AFB | 34.6 | 2875 | 117.4 | 105 | 67 | 102 | 65 | 101 | 64 | 98 | 62 | 70 | 68 | 31 | 19 | 23 | 26 | 2887 |
Georgetown RS | 38.9 | 3001 | 120.8 | 98 | 64 | 95 | 63 | 94 | 63 | 90 | 61 | 68 | 66 | 31 | 18 | 24 | 27 | - |
Giant Forest | 36.6 | 6412 | 118.8 | 84 | 56 | 81 | 55 | 80 | 55 | 77 | 53 | 60 | 58 | 26 | 5 | 13 | 18 | - |
Gillespie Field | 32.8 | 385 | 117.0 | 98 | 71 | 91 | 70 | 89 | 70 | 85 | 68 | 73 | 71 | 30 | 24 | 29 | 32 | - |
Gilroy | 37 | 194 | 121.6 | 101 | 70 | 93 | 68 | 91 | 67 | 86 | 65 | 72 | 69 | 25 | 23 | 28 | 31 | - |
Glen Avon | 34 | 827 | 117.5 | 105 | 70 | 101 | 69 | 99 | 69 | 95 | 67 | 74 | 72 | 35 | 28 | 33 | 35 | - |
Glendale | 34.2 | 563 | 118.3 | 101 | 70 | 96 | 68 | 94 | 68 | 90 | 67 | 73 | 71 | 28 | 30 | 35 | 37 | - |
Glendora | 34.1 | 822 | 117.9 | 102 | 69 | 98 | 68 | 96 | 68 | 92 | 67 | 73 | 71 | 35 | 30 | 35 | 37 | - |
Glennville | 35.7 | 3140 | 118.7 | 97 | 67 | 94 | 66 | 93 | 66 | 90 | 64 | 70 | 68 | 43 | 11 | 18 | 23 | 4423 |
Gold Rock Rch | 32.9 | 485 | 114.8 | 113 | 73 | 110 | 72 | 109 | 72 | 106 | 70 | 79 | 77 | 28 | 31 | 36 | 38 | - |
Golden Hills | 35.1 | 4000 | 118.5 | 97 | 66 | 93 | 65 | 92 | 65 | 89 | 64 | 69 | 67 | 33 | 13 | 20 | 24 | - |
Granada Hills | 34.4 | 1032 | 118.5 | 100 | 70 | 95 | 68 | 93 | 68 | 89 | 66 | 73 | 70 | 37 | 28 | 31 | 34 | 664 |
Grand Terrace | 34.1 | 1000 | 117.3 | 105 | 70 | 102 | 68 | 101 | 68 | 97 | 67 | 74 | 72 | 35 | 28 | 33 | 36 | 611 |
Grant Grove | 36.7 | 6600 | 119 | 82 | 56 | 78 | 55 | 77 | 54 | 74 | 52 | 59 | 57 | 26 | 6 | 14 | 19 | 7044 |
Grass Valley | 39.2 | 2400 | 121.1 | 99 | 67 | 96 | 65 | 95 | 65 | 91 | 63 | 69 | 67 | 29 | 19 | 25 | 28 | - |
Graton | 38.4 | 200 | 122.9 | 95 | 68 | 91 | 67 | 88 | 66 | 82 | 64 | 70 | 68 | 34 | 22 | 28 | 31 | 3409 |
Greenacres | 35.3 | 400 | 119.1 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 34 | 26 | 31 | 35 | 934 |
Greenfield | 36.2 | 287 | 121.2 | 92 | 67 | 88 | 65 | 87 | 65 | 84 | 64 | 70 | 68 | 32 | 22 | 27 | 30 | 1020 |
Grossmont | 32.7 | 530 | 117 | 96 | 69 | 89 | 68 | 88 | 68 | 84 | 66 | 71 | 69 | 23 | 31 | 36 | 38 | - |
Grover City | 35.1 | 100 | 120.6 | 93 | 69 | 86 | 64 | 84 | 64 | 80 | 62 | 67 | 65 | 18 | 30 | 34 | 37 | - |
Guadalupe | 35 | 85 | 120.6 | 92 | 66 | 86 | 64 | 84 | 64 | 79 | 62 | 67 | 65 | 18 | 28 | 32 | 35 | 1035 |
Hacienda Hts | 34 | 300 | 118 | 100 | 69 | 96 | 68 | 94 | 68 | 90 | 67 | 73 | 71 | 28 | 31 | 36 | 38 | - |
Haiwee | 36.1 | 3825 | 118 | 102 | 65 | 99 | 64 | 98 | 64 | 95 | 62 | 68 | 66 | 27 | 15 | 22 | 26 | 3700 |
Half Moon Bay | 37.5 | 60 | 122.4 | 83 | 64 | 76 | 62 | 74 | 61 | 69 | 59 | 65 | 63 | 15 | 32 | 37 | 39 | 3843 |
Hamilton AFB | 38.1 | 3 | 122.5 | 95 | 69 | 88 | 67 | 86 | 67 | 81 | 65 | 73 | 70 | 28 | 27 | 30 | 32 | 3311 |
Hanford | 36.3 | 242 | 119.7 | 102 | 71 | 99 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 37 | 22 | 28 | 31 | 2736 |
Happy Camp RS | 41.8 | 1150 | 123.4 | 103 | 67 | 97 | 66 | 96 | 66 | 92 | 65 | 69 | 67 | 41 | 18 | 24 | 27 | 4263 |
Hat Creek PH 1 | 40.9 | 3015 | 121.6 | 99 | 65 | 96 | 64 | 95 | 64 | 91 | 62 | 68 | 66 | 48 | 2 | 7 | 17 | 5689 |
Hawaiian Gardens | 33.8 | 75 | 118.1 | 97 | 70 | 91 | 69 | 89 | 69 | 84 | 67 | 72 | 70 | 23 | 32 | 37 | 39 | - |
Hawthorne | 33.9 | 70 | 118.4 | 92 | 69 | 85 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 16 | 37 | 40 | 42 | - |
Hayfield Pumps | 33.7 | 1370 | 115.6 | 112 | 71 | 108 | 70 | 107 | 70 | 104 | 68 | 77 | 75 | 31 | 24 | 29 | 32 | 1529 |
Hayward | 37.7 | 530 | 122.1 | 92 | 66 | 86 | 65 | 85 | 64 | 81 | 62 | 68 | 66 | 24 | 26 | 31 | 34 | 2909 |
Healdsburg | 38.6 | 102 | 122.9 | 102 | 69 | 95 | 68 | 94 | 68 | 90 | 66 | 71 | 69 | 37 | 26 | 31 | 34 | 2572 |
Hemet | 33.7 | 1655 | 117 | 109 | 70 | 104 | 69 | 103 | 69 | 101 | 67 | 74 | 72 | 40 | 20 | 25 | 28 | - |
Henshaw Dam | 33.2 | 2700 | 116.8 | 99 | 68 | 94 | 67 | 93 | 67 | 90 | 66 | 71 | 69 | 38 | 15 | 22 | 26 | 3708 |
Hercules | 38 | 15 | 122.3 | 91 | 66 | 87 | 65 | 86 | 65 | 82 | 64 | 69 | 67 | 25 | 30 | 35 | 38 | 823 |
Hermosa Beach | 33.9 | 16 | 118.4 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 12 | 38 | 42 | 45 | - |
Hesperia | 34.4 | 3191 | 117.3 | 105 | 67 | 101 | 65 | 100 | 65 | 97 | 63 | 70 | 68 | 38 | 14 | 21 | 25 | 1654 |
Hetch Hetchy | 38 | 3870 | 119.8 | 93 | 62 | 89 | 61 | 88 | 61 | 85 | 59 | 65 | 63 | 32 | 14 | 21 | 25 | 4816 |
Highland | 34.1 | 1315 | 117.2 | 106 | 70 | 102 | 69 | 101 | 69 | 97 | 68 | 74 | 72 | 36 | 26 | 31 | 34 | - |
Hillcrest Center | 35.4 | 500 | - | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 34 | 26 | 31 | 35 | - |
Hillsborough | 37.6 | 352 | 122.3 | 90 | 66 | 82 | 65 | 80 | 65 | 74 | 64 | 68 | 66 | 23 | 30 | 35 | 37 | - |
Hilt | 42 | 2900 | 122.6 | 97 | 64 | 93 | 62 | 92 | 62 | 89 | 60 | 66 | 64 | 39 | 5 | 13 | 18 | - |
Hollister | 36.9 | 280 | 121.4 | 96 | 68 | 89 | 67 | 87 | 67 | 81 | 65 | 70 | 68 | 30 | 21 | 27 | 30 | 2725 |
Hollywood | 34 | 384 | 118.4 | 96 | 70 | 89 | 69 | 87 | 69 | 83 | 67 | 72 | 70 | 20 | 36 | 41 | 44 | - |
Home Gardens | 33.9 | 678 | 117.5 | 104 | 70 | 100 | 69 | 98 | 69 | 92 | 67 | 74 | 72 | 35 | 26 | 31 | 34 | - |
Hoopa | 41 | 360 | 123.7 | 100 | 67 | 92 | 66 | 91 | 66 | 87 | 64 | 69 | 67 | 25 | 23 | 28 | 31 | - |
Huntington Beach | 33.7 | 40 | 117.8 | 91 | 69 | 83 | 67 | 81 | 67 | 76 | 66 | 71 | 69 | 14 | 34 | 38 | 41 | - |
Huntington Lake | 37.2 | 7020 | 119.2 | 80 | 55 | 77 | 54 | 76 | 53 | 73 | 51 | 58 | 56 | 25 | 3 | 11 | 16 | 7632 |
Huntington Park | 34 | 175 | 118 | 98 | 70 | 90 | 69 | 88 | 69 | 84 | 67 | 72 | 70 | 20 | 38 | 42 | 45 | - |
Idlewild | 41.9 | 1250 | 124 | 103 | 68 | 96 | 66 | 95 | 66 | 92 | 65 | 69 | 67 | 40 | 18 | 24 | 27 | - |
Idria | 36.4 | 2650 | 120.7 | 97 | 66 | 92 | 65 | 91 | 64 | 87 | 62 | 68 | 66 | 27 | 24 | 29 | 32 | 3128 |
Idyllwild | 33.7 | 5397 | 116.7 | 93 | 62 | 89 | 61 | 88 | 61 | 84 | 60 | 67 | 65 | 35 | 9 | 16 | 21 | - |
Imperial AP | 32.8 | -59 | 115.6 | 114 | 74 | 110 | 73 | 109 | 73 | 106 | 72 | 81 | 79 | 31 | 26 | 31 | 34 | 1060 |
Imperial Beach | 32.5 | 23 | 117.1 | 87 | 69 | 82 | 68 | 81 | 68 | 78 | 67 | 71 | 69 | 10 | 35 | 39 | 41 | 1839 |
Imperial CO | 32.9 | -64 | 115.6 | 112 | 73 | 108 | 72 | 107 | 72 | 104 | 71 | 80 | 78 | 31 | 29 | 34 | 36 | 976 |
Independence | 36.8 | 3950 | 118.2 | 104 | 61 | 101 | 60 | 100 | 60 | 97 | 60 | 65 | 63 | 31 | 12 | 19 | 24 | - |
Indio | 33.7 | 11 | 116.3 | 115 | 75 | 112 | 75 | 111 | 75 | 107 | 74 | 81 | 79 | 30 | 24 | 29 | 32 | 1059 |
Inglewood | 33.9 | 105 | 118 | 92 | 68 | 85 | 67 | 84 | 67 | 80 | 65 | 70 | 68 | 15 | 37 | 40 | 42 | - |
Inyokern NAS | 35.7 | 2440 | 117.8 | 110 | 71 | 106 | 68 | 105 | 68 | 102 | 66 | 75 | 71 | 37 | 15 | 22 | 26 | 2772 |
Ione | 38.3 | 298 | 120.9 | 101 | 70 | 97 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 38 | 23 | 28 | 31 | - |
Iron Mtn | 34.1 | 922 | 115.1 | 116 | 75 | 112 | 74 | 111 | 74 | 108 | 73 | 80 | 78 | 26 | 29 | 34 | 36 | 1251 |
Irvine | 33.7 | 50 | 118 | 96 | 69 | 88 | 68 | 86 | 68 | 82 | 67 | 72 | 70 | 27 | 33 | 37 | 40 | - |
Isla Vista | 34.5 | 40 | 119.9 | 90 | 69 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 20 | 33 | 38 | 40 | - |
Jess Valley | 41.3 | 5300 | 120.3 | 92 | 59 | 89 | 58 | 88 | 58 | 84 | 56 | 63 | 61 | 35 | -7 | -2 | 4 | 7045 |
John Wayne AP | 33.6 | 115 | 117.9 | 98 | 70 | 91 | 68 | 89 | 68 | 84 | 67 | 72 | 70 | 26 | 33 | 37 | 39 | 1496 |
Julian Wynola | 33.1 | 3650 | 116.8 | 96 | 66 | 91 | 64 | 90 | 64 | 87 | 62 | 69 | 67 | 39 | 20 | 24 | 26 | 4049 |
Kentfield | 38 | 120 | 122.6 | 97 | 66 | 91 | 65 | 89 | 65 | 84 | 63 | 70 | 68 | 35 | 27 | 32 | 35 | 3009 |
Kerman | 36.6 | 216 | 120.1 | 105 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 34 | 24 | 28 | 30 | 1262 |
Kern River PH 1 | 35.5 | 970 | 118.8 | 106 | 72 | 103 | 71 | 102 | 71 | 99 | 69 | 75 | 73 | 26 | 30 | 35 | 37 | 1878 |
Kern River PH 3 | 35.8 | 2703 | 118.6 | 103 | 69 | 100 | 68 | 99 | 68 | 96 | 66 | 72 | 70 | 34 | 19 | 25 | 28 | 2891 |
Kettleman Stn | 36.1 | 508 | 120.1 | 104 | 71 | 100 | 70 | 98 | 70 | 93 | 68 | 74 | 72 | 31 | 26 | 31 | 34 | 2180 |
King City | 36.2 | 320 | 121.1 | 94 | 67 | 90 | 65 | 89 | 65 | 85 | 64 | 70 | 68 | 36 | 20 | 26 | 29 | 2639 |
Kingsburg | 36.4 | 297 | 119.6 | 104 | 73 | 101 | 71 | 100 | 71 | 97 | 69 | 75 | 73 | 36 | 24 | 30 | 34 | 1300 |
Klamath | 41.5 | 25 | 124.1 | 79 | 62 | 71 | 60 | 70 | 60 | 66 | 58 | 64 | 61 | 18 | 26 | 31 | 33 | 4509 |
Knights Ferry | 37.8 | 315 | 120.6 | 103 | 70 | 99 | 68 | 98 | 68 | 94 | 67 | 73 | 71 | 37 | 19 | 25 | 28 | - |
La Canada-Flintridge | 34.2 | 1365 | 118 | 99 | 69 | 95 | 68 | 93 | 68 | 88 | 66 | 72 | 70 | 30 | 32 | 36 | 38 | - |
La Crescenta-Montrose | 34.2 | 1565 | 118 | 98 | 69 | 94 | 68 | 92 | 68 | 87 | 66 | 72 | 70 | 33 | 31 | 35 | 37 | - |
La Habra | 33.9 | 305 | 118 | 100 | 69 | 94 | 68 | 92 | 68 | 87 | 67 | 72 | 70 | 27 | 30 | 35 | 37 | - |
La Habra Heights | 34 | 400 | 118 | 100 | 69 | 94 | 68 | 92 | 68 | 87 | 67 | 72 | 70 | 27 | 30 | 35 | 37 | - |
La Mesa | 32.8 | 530 | 117 | 94 | 70 | 88 | 69 | 87 | 69 | 84 | 67 | 72 | 70 | 23 | 34 | 39 | 41 | 1567 |
La Mirada | 33.9 | 115 | 118 | 99 | 70 | 91 | 69 | 89 | 69 | 85 | 68 | 73 | 71 | 26 | 31 | 36 | 38 | - |
La Palma | 33.9 | 75 | 118 | 98 | 69 | 92 | 68 | 90 | 68 | 85 | 67 | 72 | 70 | 25 | 31 | 35 | 38 | - |
La Puente | 34 | 320 | 118 | 101 | 71 | 97 | 70 | 95 | 70 | 91 | 69 | 74 | 72 | 28 | 31 | 36 | 38 | - |
La Quinta | 33.8 | 400 | 116.3 | 116 | 74 | 112 | 73 | 111 | 73 | 108 | 72 | 79 | 78 | 34 | 26 | 32 | 34 | 332 |
La Riviera | 38.6 | 190 | 121.3 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 32 | 30 | 35 | 37 | 1025 |
La Verne | 34.1 | 1235 | 118 | 101 | 69 | 97 | 68 | 95 | 68 | 91 | 67 | 73 | 71 | 34 | 29 | 34 | 36 | - |
Ladera Heights | 34.1 | 100 | 118.4 | 91 | 67 | 84 | 67 | 83 | 67 | 79 | 66 | 71 | 69 | 14 | 37 | 40 | 42 | 383 |
Lafayette | 37.9 | 535 | 122.1 | 100 | 69 | 94 | 67 | 92 | 67 | 87 | 66 | 71 | 69 | 32 | 24 | 29 | 32 | - |
Laguna Beach | 33.5 | 35 | 117.8 | 91 | 69 | 83 | 68 | 81 | 68 | 76 | 66 | 71 | 69 | 18 | 30 | 33 | 36 | 2222 |
Laguna Niguel | 33.6 | 500 | 117.7 | 95 | 67 | 87 | 66 | 85 | 65 | 81 | 63 | 71 | 67 | 22 | 33 | 37 | 40 | - |
Lake Arrowhead | 34.2 | 5205 | 117.2 | 90 | 62 | 86 | 61 | 85 | 61 | 81 | 59 | 66 | 64 | 26 | 13 | 20 | 24 | 5310 |
Lake Elsinore | 33.7 | 1233 | 117.3 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 68 | 74 | 72 | 39 | 22 | 27 | 30 | 827 |
Lake Los Angeles | 34.7 | 2300 | 117.8 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 66 | 72 | 70 | 35 | 12 | 17 | 20 | 1455 |
Lake Spaulding | 39.3 | 5156 | 120.6 | 89 | 58 | 86 | 57 | 85 | 57 | 83 | 55 | 62 | 60 | 34 | 3 | 11 | 16 | 6447 |
Lakeland Village | 33.6 | 1233 | 117.3 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 68 | 74 | 72 | 39 | 12 | 27 | 30 | 827 |
Lakeport | 39 | 1347 | 122.9 | 97 | 67 | 93 | 66 | 92 | 65 | 88 | 63 | 69 | 67 | 41 | 20 | 26 | 29 | 3728 |
Lakeshore | 40.9 | 1075 | 119.2 | 104 | 69 | 100 | 68 | 99 | 68 | 95 | 66 | 71 | 69 | 28 | 29 | 34 | 36 | - |
Lakeside | 32.8 | 690 | 117 | 95 | 69 | 90 | 68 | 89 | 68 | 86 | 66 | 72 | 70 | 20 | 26 | 31 | 34 | - |
Lakewood | 33.9 | 45 | 118 | 98 | 70 | 90 | 68 | 88 | 68 | 84 | 66 | 72 | 70 | 22 | 33 | 37 | 40 | - |
Lamont | 35.3 | 500 | 120 | 106 | 72 | 102 | 71 | 101 | 71 | 98 | 69 | 75 | 73 | 34 | 26 | 32 | 35 | - |
Lancaster | 34.7 | 2340 | 118.2 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 66 | 72 | 70 | 35 | 12 | 17 | 20 | - |
Larksfield-Wikiup | 38.5 | 170 | 122.8 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 35 | 24 | 27 | 29 | 1249 |
Larkspur | 37.9 | 20 | 122.5 | 97 | 68 | 91 | 66 | 89 | 66 | 84 | 64 | 69 | 68 | 34 | 28 | 33 | 35 | - |
Las Plumas | 39.7 | 506 | 121.4 | 104 | 71 | 101 | 70 | 100 | 70 | 96 | 68 | 73 | 71 | 32 | 24 | 29 | 32 | - |
Lathrop | 37.8 | 22 | 121.3 | 103 | 71 | 98 | 69 | 97 | 69 | 93 | 67 | 73 | 71 | 35 | 24 | 28 | 30 | 1300 |
Lava Beds | 41.7 | 4770 | 121.5 | 93 | 59 | 89 | 58 | 88 | 58 | 84 | 56 | 63 | 61 | 41 | -1 | 4 | 11 | - |
Lawndale | 33.9 | 66 | 118 | 92 | 69 | 85 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 16 | 37 | 40 | 42 | - |
Le Grand | 37.2 | 255 | 120.3 | 101 | 70 | 96 | 68 | 95 | 68 | 91 | 66 | 72 | 70 | 38 | 23 | 28 | 31 | 2696 |
Lemon Grove | 32.7 | 437 | 117.2 | 96 | 71 | 88 | 69 | 87 | 69 | 84 | 67 | 72 | 70 | 19 | 34 | 38 | 41 | - |
Lemoncove | 36.4 | 513 | 119 | 105 | 72 | 102 | 70 | 101 | 70 | 98 | 68 | 72 | 70 | 38 | 25 | 38 | 41 | 2513 |
Lemoore NAS | 36.3 | 228 | 120 | 104 | 72 | 101 | 71 | 100 | 71 | 97 | 69 | 74 | 72 | 37 | 19 | 25 | 28 | 2960 |
Lennox | 33.9 | 71 | 117.8 | 92 | 69 | 85 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 16 | 37 | 41 | 44 | - |
Lincoln Village | 38 | 12 | 121.3 | 101 | 70 | 96 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 37 | 24 | 28 | 30 | 1334 |
Linda | 39 | 60 | 121.6 | 105 | 72 | 102 | 70 | 101 | 70 | 97 | 68 | 74 | 72 | 30 | 27 | 32 | 35 | 1160 |
Lindsay | 36.2 | 395 | 119.1 | 105 | 72 | 101 | 71 | 100 | 71 | 97 | 69 | 74 | 72 | 40 | 24 | 29 | 32 | 2634 |
Little Panoche | 36.8 | 677 | 120.7 | 100 | 68 | 94 | 67 | 92 | 67 | 86 | 66 | 71 | 69 | 33 | 23 | 28 | 31 | - |
Live Oak | 39.2 | 75 | 121.7 | 105 | 70 | 102 | 69 | 101 | 69 | 97 | 69 | 73 | 71 | 36 | 24 | 29 | 32 | 1160 |
Livermore | 37.7 | 490 | 122 | 100 | 69 | 95 | 68 | 93 | 68 | 88 | 67 | 71 | 70 | 35 | 22 | 25 | 28 | 3012 |
Livingston | 37.3 | 165 | 120.7 | 103 | 72 | 100 | 70 | 99 | 70 | 95 | 68 | 74 | 72 | 39 | 24 | 30 | 34 | 1244 |
Llano Shawnee | 34.5 | 3820 | 117.8 | 104 | 68 | 99 | 67 | 98 | 67 | 95 | 65 | 71 | 69 | 31 | 21 | 27 | 31 | - |
Lodgepole | 36.6 | 6735 | 118.7 | 84 | 57 | 80 | 56 | 80 | 56 | 78 | 54 | 60 | 58 | 26 | -4 | 1 | 7 | - |
Lodi | 38.1 | 40 | 121.3 | 101 | 70 | 97 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 38 | 23 | 28 | 31 | 2859 |
Loma Linda | 34 | 1150 | 117.5 | 106 | 70 | 103 | 69 | 102 | 69 | 99 | 67 | 74 | 72 | 36 | 27 | 32 | 35 | - |
Lomita | 33.8 | 56 | 119 | 95 | 69 | 87 | 68 | 85 | 68 | 81 | 66 | 71 | 69 | 18 | 33 | 38 | 40 | - |
Lompoc | 34.9 | 95 | 120.5 | 84 | 63 | 77 | 62 | 76 | 62 | 72 | 60 | 65 | 63 | 18 | 26 | 31 | 34 | 2888 |
Long Beach | 33.7 | 34 | 118.2 | 97 | 70 | 88 | 68 | 86 | 67 | 82 | 65 | 65 | 63 | 18 | 35 | 31 | 34 | - |
Long Beach AP | 33.8 | 25 | 118.2 | 99 | 71 | 90 | 69 | 88 | 68 | 84 | 66 | 73 | 71 | 21 | 33 | 38 | 41 | 1606 |
Loomis | 38.8 | 408 | 121.2 | 107 | 71 | 103 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 39 | 21 | 27 | 30 | - |
Los Alamitos NAS | 33.8 | 30 | 118.1 | 98 | 71 | 89 | 69 | 87 | 69 | 83 | 68 | 73 | 71 | 23 | 32 | 37 | 39 | 1740 |
Los Altos | 37.3 | 163 | 122 | 96 | 68 | 88 | 65 | 86 | 64 | 80 | 62 | 70 | 68 | 26 | 28 | 33 | 35 | - |
Los Altos Hills | 37.3 | 183 | 122.1 | 93 | 67 | 85 | 64 | 83 | 64 | 77 | 63 | 68 | 66 | 25 | 28 | 33 | 35 | 1103 |
Los Angeles AP | 33.9 | 97 | 118.4 | 91 | 67 | 84 | 67 | 83 | 67 | 79 | 66 | 71 | 69 | 14 | 37 | 40 | 42 | 1819 |
Los Angeles CO | 34 | 270 | 118.2 | 99 | 69 | 92 | 68 | 90 | 68 | 86 | 67 | 72 | 70 | 21 | 38 | 41 | 43 | 1245 |
Los Banos | 37 | 120 | 120.9 | 100 | 70 | 96 | 68 | 94 | 68 | 88 | 67 | 72 | 70 | 42 | 22 | 28 | 31 | 2616 |
Los Banos Res | 37 | 407 | 120.9 | 101 | 70 | 97 | 68 | 95 | 68 | 89 | 67 | 72 | 70 | 42 | 23 | 29 | 31 | - |
Los Gatos | 37.2 | 365 | 122 | 98 | 69 | 90 | 67 | 88 | 67 | 82 | 66 | 71 | 69 | 32 | 26 | 31 | 34 | 2741 |
Los Serranos | 34.1 | 714 | 117.7 | 104 | 70 | 100 | 69 | 98 | 69 | 94 | 68 | 74 | 72 | 35 | 27 | 32 | 35 | 706 |
Lucas Vly-Marinwood | 38.3 | 20 | 122.6 | 79 | 63 | 74 | 62 | 71 | 61 | 65 | 59 | 64 | 62 | 12 | 30 | 35 | 37 | 874 |
Lucerne Valley | 34.5 | 2957 | 117 | 105 | 67 | 101 | 66 | 100 | 66 | 98 | 64 | 71 | 69 | 38 | 12 | 19 | 24 | - |
Lynwood | 33.9 | 88 | 118 | 98 | 70 | 90 | 69 | 88 | 69 | 83 | 67 | 72 | 70 | 21 | 32 | 37 | 39 | - |
Madera | 37 | 268 | 120.1 | 105 | 72 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 40 | 24 | 29 | 32 | 2673 |
Madera Acres | 36.9 | 275 | 120.1 | 105 | 72 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 40 | 24 | 29 | 32 | 1250 |
Manhattan Beach | 33.9 | 120 | 118 | 91 | 69 | 84 | 68 | 83 | 68 | 79 | 66 | 71 | 69 | 12 | 38 | 42 | 45 | - |
Manteca | 37.8 | 34 | 121.2 | 102 | 70 | 97 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 37 | 24 | 29 | 32 | - |
Manzanita Lake | 40.5 | 5850 | 121.6 | 87 | 58 | 84 | 57 | 83 | 57 | 79 | 55 | 61 | 59 | 34 | -3 | 2 | 8 | 7617 |
March AFB | 33.9 | 1511 | 117.3 | 103 | 70 | 99 | 68 | 98 | 67 | 94 | 65 | 74 | 71 | 34 | 23 | 30 | 33 | 2089 |
Maricopa | 35.1 | 675 | 119.4 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 29 | 25 | 30 | 33 | 2302 |
Marina | 36.7 | 20 | 121.8 | 86 | 66 | 77 | 63 | 75 | 63 | 70 | 61 | 67 | 64 | 18 | 32 | 37 | 40 | - |
Marina del Rey | 34.1 | 40 | 118.5 | 91 | 69 | 84 | 68 | 83 | 68 | 79 | 66 | 71 | 69 | 12 | 38 | 42 | 45 | 383 |
Markley Cove | 38.5 | 480 | 122.1 | 104 | 70 | 99 | 69 | 97 | 69 | 93 | 67 | 72 | 70 | 39 | 23 | 29 | 31 | - |
Martinez FS | 38 | 40 | 122.1 | 99 | 67 | 94 | 66 | 92 | 66 | 88 | 65 | 71 | 69 | 36 | 28 | 33 | 35 | - |
Marysville | 39.2 | 60 | 121.6 | 105 | 72 | 102 | 70 | 101 | 70 | 97 | 68 | 74 | 72 | 36 | 27 | 32 | 35 | 2552 |
Mather AFB | 38.6 | 96 | 121.3 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 35 | 28 | 33 | 35 | - |
Maywood | 34 | 170 | 118 | 97 | 70 | 91 | 69 | 89 | 69 | 85 | 67 | 72 | 70 | 21 | 34 | 38 | 41 | - |
McClellan AFB | 38.7 | 86 | 121.4 | 105 | 71 | 102 | 70 | 100 | 70 | 96 | 68 | 74 | 71 | 35 | 23 | 28 | 21 | 2566 |
McCloud | 41.3 | 3300 | 122.1 | 96 | 63 | 93 | 62 | 91 | 62 | 87 | 60 | 66 | 64 | 42 | 5 | 13 | 18 | 5990 |
McFarland | 35.6 | 350 | 119.2 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 69 | 74 | 72 | 36 | 22 | 25 | 28 | 1162 |
McKinleyville | 40.9 | 33 | 124.1 | 75 | 61 | 69 | 59 | 68 | 59 | 65 | 58 | 61 | 60 | 11 | 28 | 31 | 33 | 1995 |
Mecca FS | 33.6 | -180 | 116.1 | 115 | 75 | 111 | 75 | 110 | 75 | 107 | 74 | 81 | 79 | 30 | 24 | 29 | 32 | 1185 |
Mendota | 36.7 | 169 | 120.4 | 105 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 34 | 24 | 28 | 30 | 1273 |
Menlo Park | 37.4 | 65 | 122.3 | 94 | 67 | 86 | 65 | 84 | 65 | 78 | 63 | 69 | 67 | 25 | 27 | 32 | 34 | - |
Mentone | 34.1 | 1700 | 117.1 | 106 | 70 | 102 | 69 | 101 | 69 | 98 | 67 | 74 | 72 | 34 | 27 | 32 | 35 | 741 |
Merced AP | 37.3 | 153 | 120.6 | 103 | 71 | 100 | 69 | 99 | 69 | 95 | 67 | 73 | 71 | 36 | 21 | 27 | 30 | 2653 |
Mill Creek | 35.1 | 2940 | 117 | 102 | 67 | 97 | 66 | 96 | 66 | 94 | 65 | 70 | 68 | 28 | 28 | 33 | 36 | - |
Mill Valley | 37.9 | 80 | 122.6 | 97 | 68 | 91 | 66 | 89 | 66 | 84 | 64 | 70 | 68 | 28 | 28 | 33 | 35 | 3400 |
Millbrae | 37.6 | 10 | 122.4 | 90 | 66 | 82 | 63 | 80 | 63 | 74 | 61 | 67 | 65 | 24 | 30 | 35 | 37 | - |
Milpitas | 37.4 | 15 | 121.9 | 94 | 68 | 87 | 65 | 85 | 65 | 79 | 63 | 70 | 67 | 27 | 27 | 32 | 35 | - |
Mineral | 40.4 | 4911 | 121.6 | 90 | 60 | 87 | 59 | 86 | 59 | 82 | 57 | 63 | 61 | 38 | 2 | 7 | 14 | 7257 |
Mira Loma | 34 | 700 | 117.5 | 105 | 70 | 101 | 69 | 99 | 68 | 95 | 66 | 74 | 72 | 34 | 25 | 33 | 36 | 600 |
Miramar AFS | 32.9 | 477 | 117.1 | 97 | 69 | 91 | 68 | 90 | 68 | 86 | 67 | 72 | 70 | 22 | 32 | 36 | 38 | 1532 |
Miramonte | 34.4 | 750 | 119.1 | 102 | 71 | 97 | 69 | 95 | 69 | 91 | 68 | 73 | 71 | 38 | 25 | 29 | 32 | 771 |
Mission Viejo | 33.6 | 350 | 118 | 95 | 67 | 87 | 66 | 85 | 65 | 81 | 63 | 71 | 67 | 22 | 33 | 37 | 40 | - |
Mitchell Caverns | 34.9 | 4350 | 117.0 | 102 | 64 | 98 | 63 | 97 | 63 | 94 | 61 | 69 | 67 | 29 | 21 | 27 | 30 | - |
Modesto | 37.6 | 91 | 121 | 102 | 73 | 99 | 70 | 98 | 70 | 95 | 68 | 75 | 72 | 36 | 25 | 30 | 33 | 2671 |
Moffett Field NAS | 37.4 | 39 | 122.1 | 89 | 68 | 84 | 66 | 82 | 66 | 78 | 64 | 70 | 68 | 23 | 30 | 34 | 36 | 2511 |
Mojave | 35.1 | 2735 | 118.2 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 66 | 71 | 69 | 35 | 16 | 22 | 26 | 3012 |
Mono Lake | 38 | 6450 | 119.2 | 91 | 58 | 88 | 57 | 87 | 57 | 84 | 55 | 62 | 60 | 32 | 4 | 12 | 17 | 6518 |
Monrovia | 34.2 | 562 | 118.3 | 100 | 69 | 96 | 68 | 94 | 68 | 90 | 67 | 73 | 71 | 30 | 33 | 38 | 41 | - |
Montague | 41.8 | 2648 | 122.5 | 99 | 66 | 95 | 65 | 94 | 65 | 90 | 63 | 69 | 67 | 39 | 3 | 11 | 16 | 5474 |
Montclair | 34 | 1220 | 117 | 104 | 69 | 100 | 68 | 98 | 68 | 94 | 66 | 73 | 71 | 35 | 28 | 33 | 35 | - |
Montebello | 34 | 205 | 118.1 | 98 | 69 | 93 | 68 | 91 | 68 | 86 | 67 | 72 | 70 | 24 | 33 | 37 | 39 | - |
Monterey AP | 36.6 | 245 | 121.9 | 86 | 65 | 77 | 62 | 75 | 62 | 70 | 61 | 66 | 63 | 20 | 30 | 35 | 38 | 3556 |
Monterey CO | 36.6 | 345 | 121.9 | 87 | 65 | 78 | 62 | 76 | 62 | 71 | 61 | 66 | 63 | 20 | 32 | 37 | 40 | 3169 |
Monterey Park | 34 | 380 | 118 | 99 | 69 | 94 | 68 | 92 | 68 | 87 | 67 | 72 | 70 | 23 | 30 | 35 | 37 | - |
Monticello Dam | 38.5 | 505 | 122.1 | 105 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 39 | 26 | 31 | 34 | - |
Moraga | 37.8 | 600 | 122.2 | 99 | 68 | 93 | 66 | 91 | 66 | 86 | 64 | 70 | 68 | 27 | 21 | 26 | 29 | |
Moreno Valley | 33.9 | 1600 | 117.2 | 103 | 70 | 99 | 68 | 98 | 67 | 94 | 65 | 74 | 71 | 34 | 27 | 30 | 33 | 611 |
Morgan Hill | 37.1 | 350 | 120 | 100 | 69 | 92 | 68 | 90 | 68 | 85 | 66 | 71 | 69 | 25 | 26 | 31 | 34 | - |
Morro Bay FD | 35.4 | 115 | 120.9 | 88 | 65 | 82 | 64 | 80 | 64 | 76 | 62 | 67 | 65 | 14 | 31 | 36 | 38 | - |
Mount Baldy Notch | 34.3 | 7735 | 117.6 | 80 | 58 | 76 | 57 | 75 | 56 | 71 | 54 | 61 | 59 | 32 | 4 | 10 | 14 | - |
Mount Diablo | 37.9 | 2100 | 121.9 | 101 | 68 | 96 | 66 | 93 | 66 | 87 | 65 | 68 | 59 | 28 | 27 | 32 | 35 | 4600 |
Mount Hamilton | 37.3 | 4206 | 121.7 | 95 | 59 | 88 | 58 | 86 | 58 | 81 | 56 | 63 | 61 | 18 | 18 | 24 | 27 | 4724 |
Mount Hebron RS | 41.8 | 4250 | 122 | 92 | 60 | 88 | 59 | 86 | 59 | 82 | 57 | 63 | 61 | 42 | -10 | -4 | 0 | - |
Mount San Jacinto | 33.8 | 8417 | 116.6 | 82 | 56 | 77 | 55 | 76 | 55 | 73 | 53 | 61 | 59 | 35 | -1 | 4 | 11 | - |
Mount Shasta | 41.3 | 3535 | 122.3 | 93 | 62 | 89 | 61 | 88 | 61 | 84 | 59 | 65 | 63 | 34 | 8 | 15 | 20 | 5890 |
Mount Wilson | 34.2 | 5709 | 118.1 | 90 | 63 | 85 | 61 | 83 | 60 | 79 | 58 | 66 | 64 | 21 | 15 | 22 | 26 | 4296 |
Mountain Pass | 35.5 | 4730 | 115.5 | 100 | 65 | 96 | 64 | 95 | 64 | 92 | 63 | 68 | 66 | 29 | 11 | 18 | 23 | - |
Mountain View | 37.5 | 95 | 121.9 | 93 | 67 | 85 | 64 | 83 | 64 | 77 | 62 | 68 | 66 | 25 | 28 | 33 | 35 | - |
Muscoy | 34.2 | 1400 | 117.3 | 105 | 71 | 101 | 69 | 100 | 68 | 96 | 66 | 75 | 72 | 37 | 26 | 31 | 34 | 614 |
Nacimiento Dam | 35.8 | 770 | 120.9 | 100 | 68 | 94 | 66 | 92 | 66 | 88 | 64 | 70 | 68 | 35 | 22 | 28 | 31 | - |
Napa State Hospital | 37.3 | 60 | 122.3 | 94 | 67 | 91 | 67 | 90 | 67 | 86 | 66 | 71 | 70 | 29 | 26 | 31 | 34 | 2749 |
National City | 32.7 | 34 | 117 | 87 | 70 | 82 | 68 | 81 | 68 | 78 | 66 | 71 | 69 | 10 | 36 | 40 | 42 | - |
Needles AP | 34.8 | 913 | 114.6 | 117 | 73 | 114 | 72 | 113 | 72 | 110 | 71 | 77 | 75 | 26 | 27 | 32 | 35 | 1391 |
Nevada City | 39.3 | 2600 | 121 | 97 | 66 | 94 | 64 | 92 | 64 | 88 | 63 | 68 | 66 | 41 | 14 | 21 | 25 | 4900 |
Newark | 37.5 | 10 | 122 | 94 | 68 | 89 | 67 | 87 | 67 | 82 | 65 | 70 | 68 | 24 | 29 | 34 | 36 | - |
Newhall Soledad | 34.4 | 1243 | 118.6 | 104 | 70 | 100 | 68 | 99 | 68 | 95 | 67 | 73 | 71 | 42 | 27 | 33 | 36 | - |
Newman | 37.3 | 90 | 121.1 | 104 | 71 | 99 | 69 | 97 | 69 | 93 | 67 | 73 | 71 | 38 | 22 | 28 | 31 | - |
Newport Beach | 33.6 | 10 | 117.9 | 87 | 68 | 80 | 66 | 78 | 66 | 72 | 65 | 70 | 68 | 12 | 34 | 39 | 41 | 1952 |
Nipomo | 35 | 330 | 120.5 | 90 | 66 | 83 | 64 | 82 | 63 | 78 | 61 | 67 | 65 | 23 | 25 | 31 | 33 | 1035 |
Norco | 33.9 | 700 | 117 | 103 | 70 | 99 | 69 | 98 | 69 | 94 | 67 | 74 | 72 | 34 | 27 | 32 | 35 | - |
North Auburn | 38.9 | 1300 | 121.1 | 103 | 69 | 100 | 67 | 99 | 67 | 95 | 66 | 72 | 69 | 33 | 25 | 30 | 33 | 1518 |
North Fork RS | 37.2 | 2630 | 119.5 | 98 | 66 | 95 | 65 | 94 | 64 | 92 | 62 | 69 | 67 | 36 | 15 | 22 | 26 | - |
North Highlands | 38.6 | 45 | 121.4 | 104 | 71 | 100 | 69 | 98 | 69 | 94 | 67 | 73 | 71 | 35 | 23 | 28 | 31 | 2566 |
North Hollywood | 34.2 | 619 | 118.4 | 102 | 70 | 97 | 69 | 95 | 69 | 91 | 67 | 73 | 71 | 31 | 28 | 33 | 36 | - |
Northridge | 34.2 | 875 | 118.5 | 101 | 70 | 96 | 69 | 94 | 69 | 90 | 67 | 73 | 71 | 36 | 30 | 35 | 38 | 650 |
Norwalk | 33.9 | 97 | 118.1 | 99 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 26 | 31 | 35 | 37 | - |
Novato | 38.1 | 370 | 122.5 | 94 | 64 | 87 | 63 | 85 | 63 | 80 | 61 | 68 | 66 | 30 | 25 | 30 | 32 | - |
Oakdale | 37.8 | 215 | 120.9 | 102 | 71 | 99 | 69 | 97 | 69 | 93 | 67 | 73 | 71 | 37 | 22 | 28 | 32 | - |
Oakland AP | 37.7 | 6 | 122.2 | 91 | 66 | 84 | 64 | 82 | 64 | 77 | 62 | 67 | 65 | 20 | 32 | 34 | 37 | 2909 |
Oakland Museum | 37.8 | 30 | 122.2 | 96 | 68 | 89 | 66 | 87 | 65 | 82 | 63 | 69 | 67 | 20 | 31 | 33 | 36 | - |
Oakley | 38 | 20 | 121.7 | 102 | 70 | 97 | 68 | 95 | 68 | 91 | 66 | 70 | 69 | 34 | 22 | 28 | 31 | - |
Oceano | 35.1 | 20 | 120.6 | 93 | 69 | 86 | 64 | 84 | 64 | 80 | 62 | 67 | 65 | 18 | 30 | 34 | 37 | 795 |
Oceanside | 33.2 | 10 | 117.4 | 84 | 69 | 80 | 67 | 78 | 67 | 74 | 65 | 70 | 68 | 10 | 33 | 37 | 39 | - |
Oildale | 35.5 | 450 | 119 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 34 | 26 | 31 | 35 | - |
Ojai | 34.5 | 750 | 119.3 | 102 | 71 | 97 | 69 | 95 | 69 | 91 | 68 | 73 | 71 | 38 | 25 | 29 | 32 | 2145 |
Olivehurst | 39 | 64 | 121.6 | 105 | 72 | 102 | 70 | 101 | 70 | 97 | 68 | 74 | 72 | 36 | 27 | 32 | 35 | 1160 |
Ontario AP | 34 | 934 | 117 | 105 | 70 | 101 | 69 | 99 | 68 | 95 | 66 | 74 | 72 | 34 | 26 | 33 | 36 | 1710 |
Opal Cliffs | 37 | 125 | 122 | 94 | 68 | 88 | 66 | 86 | 66 | 81 | 64 | 69 | 67 | 28 | 27 | 32 | 35 | 1097 |
Orange | 33.6 | 194 | 118 | 99 | 70 | 92 | 68 | 90 | 68 | 85 | 67 | 72 | 70 | 27 | 33 | 37 | 40 | - |
Orange Cove | 36.6 | 431 | 119.3 | 104 | 71 | 100 | 69 | 99 | 69 | 97 | 68 | 73 | 71 | 38 | 25 | 30 | 33 | 2684 |
Orangevale | 38.7 | 140 | 121.2 | 105 | 72 | 102 | 70 | 100 | 70 | 96 | 68 | 74 | 71 | 36 | 24 | 30 | 34 | - |
Orick Prairie Creek | 41.4 | 161 | 124 | 80 | 61 | 75 | 60 | 74 | 60 | 70 | 59 | 63 | 61 | 23 | 25 | 30 | 33 | 4816 |
Orinda | 37.9 | 550 | 122.2 | 99 | 68 | 93 | 66 | 91 | 66 | 86 | 64 | 70 | 68 | 32 | 21 | 26 | 29 | - |
Orland | 39.8 | 254 | 122.2 | 105 | 71 | 102 | 70 | 101 | 70 | 97 | 68 | 73 | 71 | 36 | 22 | 28 | 31 | 2824 |
Orleans | 41.3 | 403 | 123.5 | 104 | 70 | 97 | 68 | 95 | 68 | 91 | 66 | 71 | 69 | 42 | 21 | 27 | 30 | 3628 |
Orosi | 36.5 | 400 | 119.3 | 104 | 73 | 101 | 70 | 100 | 70 | 96 | 69 | 75 | 73 | 36 | 24 | 30 | 34 | 1130 |
Oroville East | 39.5 | 171 | 121.6 | 106 | 71 | 104 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 37 | 25 | 30 | 33 | 1385 |
Oroville RS | 39.5 | 300 | 121.6 | 106 | 71 | 104 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 37 | 25 | 30 | 33 | - |
Otay-Castle Pk | 32.6 | 500 | 117 | 87 | 68 | 81 | 66 | 79 | 65 | 74 | 63 | 69 | 67 | 10 | 33 | 38 | 40 | - |
Oxnard AFB | 34.2 | 49 | 119.2 | 94 | 69 | 86 | 68 | 84 | 68 | 79 | 67 | 71 | 69 | 21 | 30 | 34 | 37 | 2068 |
Pacific Grove | 36.7 | 114 | 122 | 87 | 66 | 78 | 63 | 76 | 63 | 71 | 61 | 67 | 64 | 19 | 31 | 35 | 37 | - |
Pacifica | 37.6 | 13 | 122 | 87 | 65 | 79 | 62 | 77 | 62 | 71 | 60 | 66 | 64 | 16 | 31 | 35 | 37 | - |
Pacoima | 34.3 | 895 | 118.4 | 104 | 71 | 99 | 70 | 98 | 70 | 94 | 68 | 74 | 72 | 35 | 29 | 34 | 37 | 664 |
Palermo | 39.4 | 154 | 121.5 | 106 | 71 | 104 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 37 | 25 | 30 | 33 | 1170 |
Palm Desert | 33.7 | 200 | 116.5 | 116 | 74 | 112 | 73 | 111 | 73 | 108 | 72 | 79 | 78 | 34 | 26 | 32 | 34 | - |
Palm Desert Country | 33.7 | 243 | 116.3 | 116 | 74 | 112 | 73 | 111 | 73 | 108 | 72 | 79 | 78 | 34 | 26 | 32 | 34 | 374 |
Palm Springs | 33.8 | 411 | 116.5 | 117 | 74 | 113 | 73 | 112 | 73 | 109 | 72 | 79 | 78 | 35 | 26 | 31 | 34 | 1109 |
Palmdale AP | 34.6 | 2517 | 118.1 | 107 | 67 | 103 | 67 | 102 | 66 | 98 | 64 | 71 | 69 | 33 | 12 | 20 | 24 | 2929 |
Palmdale CO | 34.6 | 2596 | 118.1 | 106 | 67 | 102 | 67 | 101 | 66 | 97 | 64 | 71 | 69 | 35 | 13 | 21 | 25 | 2908 |
Palo Alto | 37.5 | 25 | 122.1 | 93 | 66 | 85 | 64 | 83 | 64 | 77 | 62 | 68 | 66 | 25 | 26 | 31 | 34 | 2891 |
Palomar Obsy | 33.4 | 5545 | 116.9 | 90 | 62 | 85 | 61 | 84 | 61 | 80 | 59 | 66 | 64 | 22 | 16 | 20 | 23 | 4141 |
Palos Verdes | 33.8 | 216 | 119 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 14 | 38 | 43 | 46 | - |
Panorama City | 34.2 | 801 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 32 | 28 | 33 | 36 | 664 |
Paradise | 39.8 | 1750 | 121.6 | 102 | 69 | 99 | 67 | 98 | 67 | 94 | 66 | 71 | 69 | 34 | 25 | 30 | 33 | - |
Paramount | 33.9 | 70 | 117 | 98 | 70 | 90 | 69 | 88 | 69 | 84 | 67 | 72 | 70 | 22 | 32 | 37 | 40 | - |
Parker Res | 34.3 | 738 | 114.2 | 115 | 74 | 112 | 73 | 111 | 73 | 108 | 72 | 79 | 77 | 26 | 32 | 37 | 40 | 1223 |
Parkway-South Sacramento | 38.5 | 17 | 121.4 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 32 | 30 | 35 | 37 | 1150 |
Parlier | 36.6 | 320 | 119.5 | 104 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 38 | 24 | 30 | 34 | 1262 |
Pasadena | 34.2 | 864 | 118.2 | 99 | 69 | 94 | 68 | 92 | 68 | 88 | 67 | 73 | 71 | 30 | 32 | 37 | 40 | 1551 |
Paso Robles AP | 35.7 | 815 | 120.7 | 104 | 66 | 97 | 66 | 96 | 66 | 92 | 65 | 70 | 68 | 40 | 19 | 23 | 26 | 2973 |
Paso Robles CO | 35.6 | 700 | 120.7 | 102 | 65 | 95 | 65 | 94 | 65 | 90 | 65 | 69 | 67 | 44 | 16 | 20 | 23 | 2885 |
Patterson | 37.4 | 97 | 121.1 | 101 | 72 | 96 | 70 | 94 | 69 | 90 | 67 | 74 | 72 | 36 | 24 | 30 | 34 | 1240 |
Pedley | 34 | 718 | 117.5 | 105 | 70 | 101 | 69 | 99 | 68 | 95 | 66 | 74 | 72 | 34 | 26 | 33 | 36 | 600 |
Pendleton MCB | 33.3 | 63 | 117.3 | 92 | 68 | 87 | 67 | 85 | 67 | 81 | 66 | 71 | 69 | 22 | 34 | 39 | 41 | 1532 |
Pendleton MCB Coast | 33.2 | 24 | 117.4 | 84 | 69 | 80 | 67 | 79 | 67 | 75 | 65 | 70 | 68 | 10 | 39 | 44 | 46 | 1782 |
Perris | 33.8 | 1470 | 117.2 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 68 | 74 | 72 | 39 | 22 | 27 | 30 | - |
Petaluma FS 2 | 38.2 | 16 | 122.6 | 98 | 69 | 92 | 67 | 90 | 67 | 85 | 66 | 72 | 69 | 31 | 24 | 29 | 32 | 2959 |
Pico Rivera | 34 | 180 | 118 | 98 | 70 | 91 | 69 | 89 | 69 | 85 | 67 | 72 | 70 | 24 | 31 | 35 | 38 | - |
Piedmont | 37.8 | 325 | 122 | 96 | 68 | 89 | 66 | 87 | 65 | 82 | 63 | 70 | 68 | 23 | 31 | 33 | 36 | - |
Pinnacles NM | 36.5 | 1307 | 121.2 | 98 | 68 | 94 | 67 | 93 | 66 | 89 | 64 | 70 | 68 | 45 | 20 | 26 | 29 | 2956 |
Pinole | 38 | 10 | 122.3 | 91 | 66 | 87 | 65 | 86 | 65 | 82 | 64 | 69 | 67 | 25 | 30 | 35 | 38 | - |
Pismo Beach | 35.1 | 80 | 120.6 | 92 | 66 | 85 | 64 | 84 | 64 | 80 | 62 | 67 | 65 | 16 | 30 | 34 | 37 | 2756 |
Pittsburg | 38 | 50 | 121.8 | 102 | 70 | 97 | 68 | 95 | 68 | 90 | 67 | 72 | 70 | 34 | 26 | 32 | 35 | - |
Placentia | 33.9 | 323 | 118 | 101 | 69 | 93 | 68 | 91 | 68 | 87 | 67 | 73 | 71 | 28 | 30 | 34 | 37 | - |
Placerville | 38.7 | 1890 | 120.8 | 101 | 67 | 98 | 66 | 97 | 66 | 93 | 65 | 70 | 68 | 42 | 20 | 26 | 29 | 4086 |
Placerville IFG | 38.7 | 2755 | 120.8 | 100 | 66 | 97 | 65 | 96 | 65 | 92 | 64 | 69 | 67 | 42 | 23 | 28 | 31 | - |
Platina | 40.4 | 2260 | 122.9 | 96 | 65 | 92 | 64 | 91 | 63 | 87 | 61 | 67 | 65 | 36 | 13 | 20 | 24 | - |
Pleasant Hill | 37.9 | 102 | 122 | 96 | 68 | 93 | 67 | 92 | 67 | 88 | 65 | 70 | 68 | 34 | 25 | 30 | 33 | - |
Pleasanton | 37.6 | 350 | 121.8 | 97 | 68 | 94 | 67 | 93 | 67 | 89 | 65 | 70 | 68 | 35 | 24 | 29 | 32 | - |
Point Arena | 38.9 | 100 | 123.7 | 76 | 62 | 72 | 60 | 71 | 60 | 67 | 58 | 63 | 61 | 19 | 29 | 32 | 34 | 4747 |
Point Arguello | 34.6 | 76 | 120.7 | 75 | 64 | 71 | 63 | 69 | 62 | 65 | 59 | 65 | 63 | 17 | 29 | 32 | 35 | 3826 |
Point Mugu | 34.1 | 14 | 119.1 | 88 | 68 | 81 | 67 | 79 | 67 | 75 | 66 | 70 | 68 | 15 | 33 | 37 | 39 | 2328 |
Point Piedras Blancas | 35.7 | 59 | 121.3 | 73 | 60 | 67 | 59 | 65 | 59 | 61 | 57 | 62 | 60 | 10 | 36 | 41 | 43 | 3841 |
Pomona Cal Poly | 34.1 | 740 | 117.8 | 102 | 70 | 98 | 69 | 97 | 69 | 93 | 67 | 74 | 72 | 36 | 27 | 32 | 35 | 1971 |
Port Chicago ND | 38 | 50 | 122 | 98 | 69 | 94 | 68 | 92 | 68 | 88 | 66 | 71 | 69 | 34 | 28 | 33 | 36 | - |
Port Hueneme | 34.2 | 13 | 119 | 88 | 68 | 81 | 67 | 79 | 67 | 75 | 66 | 70 | 68 | 15 | 33 | 37 | 39 | 2334 |
Porterville | 36.1 | 393 | 119 | 106 | 71 | 102 | 70 | 101 | 70 | 97 | 69 | 74 | 72 | 36 | 25 | 30 | 33 | 2456 |
Portola | 39.8 | 4850 | 120.5 | 92 | 63 | 89 | 61 | 88 | 61 | 84 | 59 | 65 | 63 | 48 | -9 | -3 | 1 | 7111 |
Posey 3 E | 35.8 | 4960 | 119 | 89 | 62 | 86 | 61 | 85 | 61 | 82 | 59 | 65 | 63 | 26 | 9 | 16 | 21 | - |
Potter Valley PH | 39.4 | 1015 | 123.1 | 101 | 68 | 96 | 67 | 94 | 67 | 89 | 65 | 70 | 68 | 40 | 20 | 26 | 29 | 3276 |
Poway Valley | 33 | 500 | 117 | 100 | 70 | 94 | 69 | 93 | 69 | 89 | 68 | 73 | 71 | 26 | 29 | 33 | 35 | - |
Priest Valley | 36.2 | 2300 | 120.7 | 97 | 66 | 93 | 65 | 92 | 65 | 88 | 63 | 69 | 67 | 34 | 13 | 20 | 24 | 4144 |
Prunedale | 36.6 | 260 | 121.7 | 86 | 66 | 83 | 65 | 82 | 64 | 79 | 62 | 68 | 66 | 20 | 26 | 31 | 34 | 1100 |
Quartz Hill | 34.6 | 2428 | 118.2 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 66 | 72 | 70 | 35 | 12 | 17 | 20 | 1455 |
Quincy | 39.9 | 3409 | 120.9 | 101 | 64 | 98 | 63 | 97 | 63 | 93 | 62 | 68 | 66 | 45 | 1 | 6 | 13 | 5763 |
Ramona Spaulding | 33.1 | 1480 | 116.8 | 103 | 70 | 97 | 69 | 96 | 69 | 92 | 68 | 73 | 71 | 40 | 22 | 28 | 31 | - |
Rancho Bernardo | 33 | 500 | 117.1 | 96 | 69 | 91 | 68 | 89 | 68 | 85 | 67 | 72 | 70 | 26 | 29 | 34 | 36 | - |
Rancho Cordova | 38.6 | 190 | 121.3 | 104 | 72 | 100 | 69 | 98 | 69 | 94 | 68 | 74 | 71 | 35 | 26 | 31 | 33 | - |
Rancho Mirage | 33.8 | 248 | 116.4 | 117 | 74 | 113 | 73 | 112 | 73 | 109 | 72 | 79 | 78 | 33 | 26 | 31 | 34 | 374 |
Rancho Palos Verdes | 33.7 | 216 | 118.2 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 14 | 38 | 43 | 46 | - |
Rancho San Diego | 32.8 | 300 | 117.0 | 94 | 69 | 86 | 68 | 85 | 68 | 82 | 66 | 71 | 69 | 30 | 34 | 38 | 41 | 404 |
Rancho Santa Margarita | 33.6 | 116 | 117.6 | 95 | 67 | 87 | 66 | 85 | 65 | 81 | 63 | 71 | 67 | 22 | 33 | 37 | 40 | 496 |
Randsburg | 35.3 | 3570 | 117.7 | 105 | 67 | 102 | 66 | 101 | 66 | 97 | 65 | 70 | 68 | 30 | 19 | 25 | 28 | 2922 |
Red Bluff AP | 40.2 | 342 | 122.3 | 107 | 70 | 104 | 69 | 102 | 68 | 98 | 66 | 73 | 71 | 31 | 24 | 29 | 31 | 2688 |
Redding FS 4 | 40.6 | 470 | 122.4 | 107 | 69 | 103 | 68 | 101 | 68 | 97 | 67 | 72 | 70 | 30 | 26 | 31 | 34 | 2544 |
Redlands | 34.1 | 1318 | 117.2 | 106 | 70 | 102 | 69 | 101 | 69 | 98 | 67 | 74 | 72 | 34 | 27 | 32 | 35 | 1993 |
Redondo Beach | 33.8 | 45 | 118.3 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 12 | 37 | 42 | 44 | - |
Redwood City | 37.5 | 31 | 122.2 | 90 | 67 | 86 | 66 | 85 | 66 | 81 | 64 | 69 | 67 | 28 | 28 | 33 | 35 | 2599 |
Reedley | 36.6 | 344 | 119.7 | 104 | 71 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 40 | 24 | 30 | 34 | - |
Reseda | 34.2 | 736 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 32 | 28 | 33 | 36 | 664 |
Rialto | 34.1 | 1254 | 117 | 105 | 70 | 101 | 69 | 100 | 68 | 96 | 66 | 74 | 72 | 35 | 28 | 33 | 35 | - |
Richardson Grove | 40 | 500 | 123.8 | 96 | 67 | 92 | 66 | 91 | 66 | 87 | 64 | 69 | 67 | 28 | 25 | 30 | 33 | - |
Richmond | 37.9 | 55 | 121.6 | 88 | 65 | 84 | 64 | 82 | 64 | 77 | 62 | 67 | 65 | 17 | 31 | 36 | 38 | 2684 |
Ridgecrest | 35.6 | 2340 | 117.8 | 110 | 70 | 106 | 68 | 105 | 68 | 102 | 66 | 75 | 71 | 35 | 15 | 22 | 26 | - |
Rio Del Mar | 37 | 50 | 121.9 | 94 | 67 | 88 | 66 | 87 | 65 | 83 | 63 | 69 | 67 | 30 | 27 | 32 | 35 | 1097 |
Rio Linda | 38.6 | 86 | 121.5 | 104 | 72 | 100 | 70 | 98 | 70 | 94 | 68 | 74 | 71 | 32 | 28 | 33 | 35 | 1290 |
Ripon | 37.7 | 61 | 121.1 | 102 | 70 | 97 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 37 | 23 | 30 | 33 | 1240 |
Riverbank | 37.7 | 133 | 120.9 | 102 | 73 | 99 | 70 | 98 | 70 | 95 | 68 | 75 | 72 | 36 | 25 | 30 | 33 | 1240 |
Riverside Exp Sta | 34 | 986 | 117.4 | 106 | 71 | 102 | 69 | 101 | 69 | 97 | 67 | 75 | 72 | 36 | 29 | 34 | 36 | - |
Riverside FS 3 | 34 | 840 | 117.4 | 104 | 70 | 100 | 69 | 99 | 68 | 95 | 65 | 74 | 72 | 37 | 27 | 32 | 35 | 1818 |
Rocklin | 38.8 | 239 | 121.2 | 108 | 72 | 104 | 70 | 103 | 70 | 99 | 69 | 74 | 72 | 39 | 20 | 26 | 29 | 3143 |
Rodeo | 38.1 | 15 | 122.3 | 93 | 67 | 90 | 66 | 88 | 66 | 84 | 64 | 70 | 68 | 23 | 28 | 33 | 36 | 823 |
Rohnert Park | 38.4 | 106 | 122.6 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 33 | 24 | 27 | 29 | - |
Rolling Hills | 33.6 | 216 | 119 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 15 | 38 | 43 | 46 | - |
Rosamond | 34.8 | 2326 | 118.2 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 66 | 71 | 69 | 35 | 16 | 22 | 26 | 1455 |
Roseland | 38.4 | 167 | 122.7 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 35 | 24 | 27 | 29 | 1249 |
Rosemead | 34 | 275 | 118 | 98 | 70 | 90 | 69 | 88 | 69 | 84 | 67 | 72 | 70 | 27 | 30 | 35 | 37 | - |
Rosemont | 38.3 | 190 | 121.4 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 32 | 30 | 35 | 37 | 1025 |
Roseville | 38.7 | 160 | 121.2 | 105 | 71 | 102 | 70 | 100 | 70 | 96 | 68 | 74 | 71 | 36 | 24 | 30 | 34 | - |
Rossmoor | 33.8 | 20 | 118.1 | 92 | 67 | 85 | 64 | 83 | 64 | 79 | 62 | 71 | 69 | 19 | 32 | 37 | 39 | - |
Rowland Hts | 33.9 | 540 | 118 | 99 | 70 | 93 | 69 | 91 | 69 | 86 | 68 | 73 | 71 | 27 | 29 | 34 | 36 | - |
Rubidoux | 34 | 792 | 117 | 106 | 71 | 102 | 70 | 101 | 70 | 97 | 68 | 75 | 73 | 36 | 27 | 32 | 35 | - |
Sacramento AP | 38.5 | 17 | 121.5 | 104 | 72 | 100 | 70 | 98 | 70 | 94 | 68 | 74 | 71 | 35 | 26 | 31 | 33 | 2843 |
Sacramento CO | 38.6 | 84 | 121.5 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 32 | 30 | 35 | 37 | - |
Saint Helena | 38.5 | 225 | 122.5 | 102 | 70 | 98 | 69 | 97 | 69 | 93 | 67 | 72 | 70 | 40 | 22 | 28 | 31 | 2878 |
Saint Mary's College | 37.8 | 623 | 122.1 | 98 | 69 | 93 | 68 | 91 | 68 | 86 | 66 | 71 | 69 | 28 | 21 | 27 | 30 | 3543 |
Salinas 3 E | 36.7 | 85 | 121.6 | 86 | 66 | 83 | 65 | 82 | 64 | 79 | 62 | 68 | 66 | 20 | 26 | 31 | 34 | - |
Salinas AP | 36.7 | 69 | 121.6 | 85 | 67 | 82 | 65 | 81 | 64 | 78 | 62 | 69 | 66 | 20 | 28 | 33 | 35 | 2959 |
Salt Springs PH | 38.5 | 3700 | 120.2 | 95 | 62 | 92 | 61 | 91 | 61 | 87 | 59 | 66 | 64 | 27 | 19 | 25 | 28 | 3857 |
Salyer RS | 40.9 | 623 | 123.6 | 102 | 69 | 95 | 67 | 93 | 66 | 87 | 64 | 70 | 68 | 33 | 22 | 28 | 31 | - |
San Anselmo | 38 | 50 | 122 | 95 | 67 | 89 | 66 | 87 | 66 | 82 | 65 | 70 | 68 | 32 | 26 | 31 | 33 | - |
San Antonio Canyon | 34.2 | 2394 | 117.7 | 100 | 68 | 96 | 67 | 94 | 67 | 90 | 65 | 72 | 70 | 33 | 29 | 35 | 39 | - |
San Antonio Mission | 36 | 1060 | 117.7 | 99 | 69 | 94 | 68 | 92 | 68 | 88 | 67 | 71 | 69 | 28 | 19 | 25 | 28 | - |
San Bernardino | 34.1 | 1125 | 117.3 | 106 | 70 | 102 | 69 | 101 | 69 | 98 | 68 | 75 | 72 | 39 | 27 | 31 | 33 | 1777 |
San Bruno | 37.7 | 20 | 122.4 | 86 | 66 | 80 | 64 | 78 | 64 | 73 | 62 | 67 | 65 | 23 | 30 | 35 | 38 | 3042 |
San Carlos | 37.5 | 26 | 122.3 | 92 | 67 | 88 | 65 | 86 | 65 | 82 | 63 | 68 | 66 | 28 | 28 | 33 | 35 | - |
San Clemente | 33.4 | 208 | 118.6 | 91 | 68 | 85 | 67 | 84 | 67 | 80 | 66 | 71 | 69 | 12 | 31 | 35 | 37 | - |
San Diego AP | 32.7 | 13 | 117.2 | 88 | 70 | 83 | 69 | 82 | 69 | 78 | 68 | 72 | 70 | 13 | 38 | 42 | 44 | 1507 |
San Dimas | 34 | 955 | 118.4 | 102 | 70 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 72 | 35 | 30 | 35 | 37 | - |
San Fernando | 34.3 | 977 | 118.5 | 104 | 71 | 99 | 70 | 98 | 70 | 94 | 68 | 74 | 72 | 37 | 30 | 35 | 37 | 1800 |
San Francisco AP | 37.6 | 8 | 122.4 | 89 | 66 | 83 | 64 | 80 | 63 | 74 | 61 | 67 | 64 | 20 | 31 | 35 | 38 | 3042 |
San Francisco CO | 37.8 | 52 | 122.4 | 84 | 65 | 79 | 63 | 77 | 62 | 71 | 60 | 66 | 63 | 14 | 38 | 41 | 44 | 3080 |
San Gabriel FD | 34.1 | 450 | 118.1 | 99 | 70 | 94 | 69 | 92 | 69 | 88 | 68 | 73 | 71 | 30 | 30 | 35 | 37 | 1532 |
San Gregorio 2 SE | 37.3 | 275 | 122.4 | 87 | 66 | 81 | 63 | 79 | 63 | 74 | 61 | 68 | 65 | 30 | 27 | 32 | 35 | - |
San Jacinto | 33.8 | 1535 | 117 | 110 | 70 | 105 | 69 | 104 | 69 | 102 | 68 | 75 | 73 | 41 | 20 | 26 | 29 | 2376 |
San Jose | 37.4 | 67 | 121.9 | 94 | 68 | 86 | 66 | 84 | 66 | 78 | 64 | 70 | 68 | 26 | 29 | 34 | 36 | 2438 |
San Leandro | 37.7 | 45 | 122.2 | 89 | 67 | 83 | 64 | 81 | 64 | 76 | 62 | 69 | 66 | 22 | 28 | 33 | 35 | - |
San Lorenzo | 37.7 | 45 | 122.1 | 89 | 67 | 83 | 64 | 81 | 64 | 76 | 62 | 69 | 66 | 23 | 28 | 33 | 36 | - |
San Luis Dam | 37.1 | 277 | 121.1 | 97 | 68 | 91 | 66 | 90 | 66 | 86 | 64 | 70 | 68 | 32 | 25 | 30 | 33 | - |
San Luis Obispo | 35.3 | 320 | 120.7 | 94 | 63 | 87 | 63 | 85 | 63 | 81 | 62 | 67 | 65 | 26 | 30 | 33 | 35 | 2498 |
San Marcos | 33.1 | 567 | 117.2 | 97 | 69 | 98 | 68 | 94 | 68 | 84 | 67 | 72 | 70 | 29 | 26 | 31 | 34 | 662 |
San Marino | 34.2 | 300 | 118.1 | 100 | 69 | 95 | 68 | 93 | 68 | 88 | 66 | 73 | 71 | 28 | 30 | 35 | 37 | - |
San Mateo | 37.5 | 21 | 122.3 | 92 | 67 | 84 | 65 | 82 | 65 | 76 | 63 | 68 | 66 | 24 | 31 | 36 | 38 | 2655 |
San Nicholas Island | 33.2 | 504 | 119.5 | 85 | 66 | 78 | 65 | 76 | 65 | 70 | 64 | 69 | 67 | 11 | 39 | 43 | 45 | 2454 |
San Pablo | 37.6 | 30 | 122.3 | 90 | 65 | 84 | 63 | 82 | 63 | 77 | 61 | 69 | 66 | 17 | 29 | 34 | 37 | - |
San Pedro | 33.7 | 10 | 118.3 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 72 | 70 | 13 | 35 | 31 | 34 | 1819 |
San Rafael | 38 | 40 | 122.6 | 96 | 67 | 90 | 65 | 88 | 65 | 83 | 63 | 71 | 68 | 29 | 30 | 35 | 37 | 2440 |
San Ramon | 37.7 | 360 | 122 | 99 | 69 | 93 | 67 | 91 | 67 | 86 | 65 | 70 | 68 | 35 | 24 | 29 | 32 | 1369 |
Sandberg | 34.8 | 4517 | 118.7 | 95 | 63 | 91 | 61 | 90 | 61 | 87 | 59 | 67 | 65 | 32 | 17 | 21 | 24 | 4427 |
Sanger | 36.7 | 364 | 119.6 | 105 | 72 | 101 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 37 | 24 | 30 | 34 | - |
Santa Ana FS | 33.8 | 115 | 117.8 | 98 | 70 | 91 | 68 | 89 | 68 | 84 | 67 | 72 | 70 | 26 | 33 | 35 | 38 | 1430 |
Santa Barbara AP | 34.4 | 9 | 119.8 | 90 | 69 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 20 | 29 | 34 | 36 | 2487 |
Santa Barbara CO | 34.4 | 5 | 119.7 | 91 | 69 | 84 | 67 | 82 | 67 | 78 | 65 | 70 | 68 | 22 | 33 | 38 | 40 | 1994 |
Santa Clara Univ | 37.4 | 88 | 121.9 | 90 | 67 | 87 | 65 | 86 | 65 | 82 | 63 | 69 | 67 | 30 | 29 | 34 | 36 | 2566 |
Santa Clarita | 34.4 | 1300 | 118.5 | 103 | 71 | 98 | 70 | 97 | 70 | 93 | 68 | 74 | 72 | 36 | 30 | 35 | 37 | - |
Santa Cruz | 37 | 125 | 122 | 94 | 68 | 88 | 66 | 86 | 66 | 81 | 64 | 69 | 67 | 28 | 27 | 32 | 35 | 3136 |
Santa Fe Springs | 33.9 | 280 | 118.1 | 99 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 24 | 31 | 36 | 38 | - |
Santa Maria AP | 34.9 | 236 | 120.5 | 90 | 66 | 83 | 64 | 82 | 63 | 78 | 61 | 67 | 65 | 23 | 25 | 31 | 33 | 3053 |
Santa Monica | 34 | 15 | 118.5 | 85 | 67 | 78 | 66 | 76 | 66 | 72 | 64 | 69 | 67 | 15 | 39 | 44 | 46 | 1873 |
Santa Paula | 34.4 | 263 | 119.1 | 101 | 71 | 94 | 70 | 92 | 70 | 87 | 68 | 73 | 71 | 28 | 28 | 33 | 35 | 2030 |
Santa Rosa | 38.5 | 167 | 122.8 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 35 | 24 | 27 | 29 | 2980 |
Santee | 32.8 | 400 | 117 | 96 | 69 | 91 | 68 | 90 | 68 | 87 | 67 | 72 | 70 | 20 | 25 | 30 | 33 | - |
Saratoga | 37.3 | 500 | 122 | 96 | 67 | 88 | 66 | 86 | 66 | 80 | 65 | 70 | 68 | 31 | 27 | 32 | 35 | - |
Sausalito | 37.9 | 10 | 122.5 | 85 | 66 | 80 | 65 | 78 | 65 | 73 | 63 | 67 | 65 | 12 | 30 | 34 | 36 | - |
Sawyer's Bar RS | 41.3 | 2169 | 123.1 | 100 | 66 | 95 | 65 | 93 | 64 | 88 | 62 | 68 | 66 | 38 | 14 | 21 | 25 | 4102 |
Scotia | 40.5 | 139 | 124.4 | 78 | 61 | 74 | 60 | 73 | 60 | 69 | 58 | 63 | 61 | 19 | 28 | 33 | 35 | 3954 |
Scotts Valley | 37 | 400 | 122 | 94 | 68 | 88 | 66 | 86 | 66 | 81 | 64 | 69 | 67 | 28 | 27 | 32 | 35 | 1097 |
Seal Beach | 33.8 | 21 | 118.1 | 94 | 69 | 86 | 68 | 84 | 67 | 80 | 65 | 71 | 69 | 15 | 35 | 40 | 42 | 1519 |
Seaside | 36.6 | 17 | 122.9 | 85 | 66 | 79 | 64 | 77 | 64 | 73 | 62 | 67 | 65 | 20 | 30 | 35 | 37 | - |
Sebastapol | 38.4 | 102 | 122.8 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 35 | 24 | 27 | 29 | 1249 |
Selma | 36.6 | 305 | 119.6 | 104 | 73 | 101 | 71 | 100 | 70 | 97 | 68 | 75 | 73 | 38 | 24 | 30 | 34 | - |
Sepulveda | 34.2 | 818 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 32 | 28 | 33 | 36 | 664 |
Shafter | 35.5 | 345 | 119.2 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 28 | 24 | 29 | 32 | 2185 |
Shasta Dam | 40.7 | 1076 | 122.4 | 105 | 69 | 101 | 68 | 99 | 68 | 95 | 67 | 72 | 70 | 27 | 29 | 34 | 36 | 2943 |
Shelter Cove | 40 | 110 | 124.1 | 80 | 61 | 73 | 60 | 72 | 59 | 68 | 57 | 63 | 61 | 15 | 34 | 39 | 41 | - |
Sherman Oaks | 34.2 | 657 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 28 | 29 | 34 | 37 | 664 |
Sierra City | 39.6 | 4230 | 120.1 | 96 | 62 | 93 | 61 | 92 | 61 | 89 | 59 | 66 | 64 | 43 | 12 | 19 | 24 | - |
Sierra Madre | 34.2 | 1153 | 118.1 | 102 | 69 | 96 | 68 | 94 | 68 | 90 | 67 | 73 | 71 | 27 | 32 | 37 | 39 | - |
Sierraville RS | 39.6 | 4975 | 120.4 | 94 | 60 | 91 | 59 | 90 | 59 | 86 | 57 | 64 | 62 | 44 | -10 | -4 | 0 | 6893 |
Signal Hill | 33.5 | 100 | 118.2 | 99 | 70 | 90 | 69 | 88 | 68 | 84 | 66 | 72 | 70 | 19 | 35 | 39 | 42 | - |
Simi Valley | 34.4 | 500 | 118.8 | 98 | 70 | 93 | 68 | 91 | 68 | 87 | 66 | 73 | 71 | 30 | 28 | 33 | 35 | - |
Solana Beach | 33 | 15 | 117.3 | 87 | 68 | 83 | 67 | 81 | 67 | 77 | 65 | 70 | 68 | 10 | 35 | 39 | 41 | - |
Soledad | 36.4 | 200 | 121.3 | 90 | 67 | 87 | 65 | 86 | 65 | 82 | 64 | 70 | 67 | 23 | 24 | 29 | 32 | 1020 |
Sonoma | 38.3 | 70 | 122.5 | 101 | 70 | 96 | 69 | 94 | 69 | 90 | 67 | 72 | 70 | 40 | 22 | 28 | 31 | 2998 |
Sonora RS | 38 | 1749 | 120.4 | 103 | 68 | 100 | 67 | 99 | 67 | 95 | 66 | 72 | 70 | 34 | 20 | 26 | 29 | 3537 |
Soquel | 37 | 50 | 122 | 94 | 67 | 88 | 66 | 86 | 65 | 81 | 63 | 69 | 67 | 24 | 27 | 32 | 35 | 1097 |
South El Monte | 34 | 270 | 118.1 | 101 | 72 | 97 | 70 | 95 | 70 | 91 | 68 | 74 | 72 | 28 | 31 | 36 | 38 | - |
South Entr Yosemite | 37.5 | 5120 | 119.6 | 92 | 61 | 88 | 60 | 87 | 60 | 84 | 59 | 64 | 62 | 36 | 8 | 15 | 20 | 5789 |
South Gate | 33.9 | 120 | 118.2 | 97 | 70 | 90 | 69 | 88 | 69 | 84 | 67 | 72 | 70 | 21 | 32 | 37 | 39 | - |
South Laguna | 33.6 | 100 | 117.7 | 91 | 69 | 83 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 18 | 30 | 33 | 36 | 586 |
South Lake Tahoe | 38.9 | 6200 | 120 | 85 | 56 | 82 | 55 | 79 | 55 | 71 | 54 | 60 | 58 | 33 | -2 | 3 | 10 | - |
South Oroville | 39.5 | 174 | 121.6 | 106 | 71 | 104 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 37 | 25 | 30 | 33 | 1385 |
South Pasadena | 34 | 657 | 118.2 | 99 | 69 | 94 | 68 | 92 | 68 | 88 | 67 | 73 | 71 | 30 | 31 | 36 | 38 | - |
South San Francisco | 37.7 | 10 | 122.4 | 87 | 67 | 81 | 64 | 78 | 64 | 72 | 62 | 68 | 65 | 20 | 32 | 36 | 38 | - |
South San Gabriel | 34.1 | 450 | 118.1 | 99 | 70 | 94 | 69 | 92 | 69 | 88 | 68 | 73 | 71 | 73 | 30 | 35 | 37 | 431 |
South Whittier | 33.9 | 300 | 118 | 100 | 70 | 92 | 69 | 90 | 69 | 84 | 68 | 73 | 71 | 30 | 31 | 36 | 38 | - |
South Yuba City | 39.1 | 59 | 121.6 | 105 | 69 | 101 | 69 | 100 | 69 | 96 | 68 | 72 | 71 | 36 | 24 | 29 | 32 | 1160 |
Spring Valley | 32.7 | 300 | 117 | 94 | 69 | 86 | 68 | 85 | 68 | 82 | 66 | 71 | 69 | 30 | 34 | 38 | 41 | - |
Squaw Valley | 39.2 | 6235 | 120.2 | 88 | 57 | 85 | 56 | 84 | 56 | 80 | 54 | 61 | 59 | 40 | -10 | -4 | 0 | - |
Squirrel Inn | 34.2 | 5680 | 117.2 | 86 | 61 | 82 | 60 | 81 | 60 | 77 | 58 | 65 | 63 | 23 | 12 | 18 | 22 | 5175 |
Stanford | 37.5 | 23 | 122.1 | 93 | 66 | 85 | 64 | 83 | 64 | 77 | 62 | 68 | 66 | 25 | 26 | 31 | 34 | 1103 |
Stanton | 33.6 | 45 | 118 | 98 | 69 | 91 | 68 | 89 | 68 | 84 | 67 | 72 | 70 | 24 | 31 | 36 | 38 | - |
Stockton AP | 37.9 | 22 | 121.3 | 103 | 71 | 98 | 69 | 97 | 69 | 93 | 67 | 73 | 71 | 35 | 24 | 28 | 30 | 2806 |
Stockton FS 4 | 38 | 12 | 121.3 | 101 | 70 | 96 | 68 | 95 | 68 | 91 | 67 | 72 | 70 | 37 | 24 | 28 | 30 | 2846 |
Stony Gorge Res | 39.6 | 791 | 122.5 | 104 | 70 | 99 | 69 | 97 | 69 | 93 | 67 | 72 | 70 | 37 | 21 | 27 | 30 | 3149 |
Strawberry Valley | 39.6 | 3808 | 121.1 | 96 | 63 | 93 | 62 | 92 | 62 | 88 | 60 | 66 | 64 | 32 | 14 | 21 | 25 | 5120 |
Studio City | 34.3 | 620 | 118.4 | 102 | 70 | 97 | 69 | 95 | 69 | 91 | 67 | 73 | 71 | 31 | 28 | 33 | 36 | 664 |
Suisun City | 38.2 | 72 | 122 | 103 | 71 | 98 | 69 | 96 | 68 | 91 | 66 | 73 | 70 | 35 | 24 | 29 | 32 | 1299 |
Sun City | 33.7 | 1420 | 117.2 | 105 | 70 | 101 | 69 | 100 | 69 | 97 | 68 | 74 | 72 | 39 | 22 | 27 | 30 | 827 |
Sunland | 34.3 | 1460 | 118.3 | 107 | 71 | 102 | 70 | 100 | 70 | 96 | 68 | 74 | 72 | 36 | 28 | 33 | 36 | - |
Sunnyvale | 37.3 | 97 | 122 | 96 | 68 | 88 | 66 | 86 | 66 | 80 | 64 | 70 | 68 | 26 | 29 | 34 | 36 | 2511 |
Susanville AP | 40.4 | 4148 | 120.6 | 98 | 62 | 95 | 61 | 94 | 61 | 90 | 59 | 66 | 64 | 38 | -1 | 4 | 11 | 6233 |
Taft | 35.1 | 987 | 119.5 | 106 | 71 | 102 | 70 | 101 | 70 | 98 | 68 | 74 | 72 | 34 | 26 | 31 | 35 | 934 |
Tahoe City | 39.2 | 6230 | 120.1 | 84 | 56 | 81 | 55 | 80 | 55 | 76 | 53 | 60 | 58 | 36 | 2 | 7 | 14 | 8085 |
Tahoe Valley AP | 38.9 | 6254 | 120.0 | 85 | 56 | 82 | 55 | 81 | 55 | 77 | 53 | 60 | 58 | 38 | -5 | 2 | 6 | - |
Tamalpais-Homestead Valley | 37.9 | 25 | 122.5 | 97 | 68 | 91 | 66 | 89 | 66 | 84 | 64 | 70 | 68 | 28 | 28 | 33 | 35 | 874 |
Tarzana | 34.2 | 800 | 118.6 | 104 | 71 | 99 | 69 | 97 | 69 | 93 | 68 | 74 | 71 | 27 | 27 | 32 | 35 | 664 |
Tehachapi | 35.1 | 3975 | 118.5 | 97 | 66 | 93 | 65 | 92 | 65 | 89 | 64 | 69 | 67 | 33 | 13 | 20 | 24 | 4494 |
Tejon Rancho | 35 | 1425 | 118.8 | 107 | 71 | 103 | 70 | 102 | 70 | 99 | 68 | 74 | 72 | 27 | 24 | 29 | 32 | 2602 |
Temecula | 33.5 | 1006 | 117.2 | 101 | 69 | 96 | 68 | 95 | 68 | 91 | 67 | 73 | 71 | 34 | 24 | 29 | 32 | - |
Temple City | 34.1 | 403 | 118.1 | 101 | 70 | 95 | 69 | 93 | 69 | 89 | 68 | 73 | 71 | 27 | 30 | 35 | 37 | - |
Termo | 40.9 | 5300 | 120.5 | 95 | 60 | 92 | 59 | 91 | 59 | 87 | 57 | 64 | 62 | 37 | -17 | -11 | -4 | - |
Thermal AP | 33.6 | -112 | 116.1 | 114 | 74 | 110 | 74 | 109 | 74 | 106 | 74 | 80 | 79 | 29 | 26 | 31 | 35 | 1154 |
Thermalito | 37.9 | 25 | 121.6 | 106 | 71 | 104 | 70 | 102 | 70 | 98 | 69 | 74 | 72 | 37 | 25 | 30 | 33 | - |
Thousand Oaks | 34.2 | 810 | 118.8 | 98 | 69 | 93 | 68 | 92 | 68 | 88 | 67 | 72 | 70 | 30 | 27 | 32 | 35 | - |
Three Rivers PH 1 | 36.5 | 1140 | 118.9 | 105 | 70 | 102 | 69 | 101 | 69 | 98 | 67 | 73 | 71 | 38 | 24 | 30 | 32 | 2642 |
Tiburon | 37.9 | 90 | 122.5 | 85 | 66 | 80 | 65 | 78 | 65 | 73 | 63 | 67 | 65 | 12 | 30 | 34 | 36 | - |
Tiger Creek PH | 38.5 | 2355 | 120.5 | 100 | 66 | 96 | 65 | 95 | 65 | 92 | 63 | 69 | 67 | 36 | 20 | 26 | 29 | 3795 |
Torrance | 33.8 | 110 | 118.3 | 93 | 69 | 86 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 18 | 32 | 37 | 39 | 1859 |
Tracy Carbona | 37.7 | 140 | 121.4 | 102 | 70 | 97 | 68 | 95 | 68 | 90 | 67 | 72 | 70 | 38 | 24 | 29 | 32 | 2704 |
Tracy Pumps | 37.8 | 61 | 121.4 | 104 | 71 | 99 | 69 | 97 | 69 | 92 | 68 | 73 | 71 | 39 | 23 | 28 | 31 | - |
Travis AFB | 38.3 | 72 | 121.9 | 103 | 71 | 98 | 69 | 96 | 68 | 91 | 66 | 73 | 70 | 35 | 24 | 29 | 32 | 2725 |
Trinity Dam | 40.8 | 2500 | 122.8 | 99 | 65 | 94 | 64 | 92 | 64 | 88 | 62 | 68 | 66 | 37 | 17 | 24 | 28 | - |
Trona | 35.8 | 1695 | 117.4 | 113 | 72 | 109 | 70 | 108 | 70 | 105 | 68 | 76 | 73 | 35 | 18 | 24 | 27 | 2415 |
Truckee RS | 39.3 | 5995 | 120.2 | 90 | 58 | 87 | 57 | 86 | 57 | 82 | 55 | 62 | 60 | 40 | -10 | -4 | 0 | 8230 |
Tujunga | 34.3 | 1820 | 118.3 | 103 | 70 | 99 | 69 | 98 | 69 | 94 | 67 | 73 | 71 | 36 | 20 | 26 | 29 | - |
Tulare | 36.2 | 290 | 119.4 | 105 | 72 | 101 | 71 | 100 | 71 | 96 | 69 | 74 | 72 | 39 | 24 | 30 | 34 | - |
Tulelake | 42 | 4035 | 121.5 | 92 | 60 | 88 | 59 | 87 | 59 | 83 | 57 | 63 | 61 | 41 | -5 | 0 | 6 | 6854 |
Turlock | 37.5 | 100 | 120.9 | 104 | 72 | 100 | 70 | 99 | 70 | 95 | 68 | 74 | 72 | 40 | 24 | 30 | 34 | - |
Turntable Creek | 40.8 | 1067 | 120.9 | 105 | 69 | 101 | 68 | 99 | 68 | 95 | 66 | 72 | 70 | 28 | 24 | 29 | 32 | - |
Tustin Foothills | 33.8 | 500 | 117.8 | 99 | 71 | 92 | 69 | 90 | 69 | 85 | 68 | 73 | 71 | 27 | 28 | 31 | 34 | 550 |
Tustin Irvine Rch | 33.7 | 118 | 117.8 | 99 | 71 | 92 | 69 | 90 | 69 | 85 | 68 | 73 | 71 | 27 | 28 | 31 | 34 | 1856 |
Twentynine Palms | 34.1 | 1975 | 116.1 | 110 | 71 | 107 | 70 | 106 | 70 | 103 | 69 | 76 | 74 | 31 | 21 | 26 | 29 | 1973 |
Twin Lakes | 38.7 | 7829 | 119.1 | 73 | 49 | 64 | 47 | 62 | 47 | 57 | 46 | 53 | 50 | 30 | -7 | -2 | 4 | 9196 |
Twitchell Dam | 35 | 582 | 120.3 | 99 | 70 | 93 | 68 | 92 | 68 | 88 | 66 | 71 | 69 | 26 | 26 | 31 | 34 | - |
UCLA | 34.1 | 430 | 118.4 | 93 | 69 | 86 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 20 | 39 | 43 | 46 | 1509 |
Ukiah | 39.2 | 623 | 123.2 | 100 | 70 | 97 | 69 | 96 | 69 | 92 | 68 | 72 | 71 | 42 | 22 | 28 | 31 | 2958 |
Union City | 37.6 | 5 | 122.1 | 90 | 67 | 87 | 66 | 85 | 65 | 81 | 63 | 69 | 67 | 20 | 25 | 30 | 33 | - |
Upland | 34.1 | 1605 | 117.7 | 102 | 69 | 98 | 68 | 96 | 68 | 92 | 66 | 73 | 71 | 31 | 29 | 34 | 36 | 2175 |
Upper Lake RS | 39.2 | 1347 | 123 | 98 | 68 | 95 | 67 | 94 | 66 | 91 | 64 | 73 | 71 | 39 | 18 | 34 | 36 | - |
Upper San Leandro | 37.8 | 394 | 122.1 | 93 | 67 | 87 | 66 | 85 | 65 | 80 | 63 | 69 | 67 | 22 | 28 | 33 | 35 | - |
Vacaville | 38.4 | 105 | 122 | 103 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 40 | 23 | 28 | 31 | 2788 |
Valinda | 34 | 340 | 117.9 | 102 | 70 | 98 | 69 | 96 | 69 | 92 | 68 | 74 | 72 | 28 | 31 | 36 | 38 | - |
Valle Vista | 33.8 | 1655 | 116.9 | 109 | 70 | 104 | 69 | 103 | 69 | 101 | 67 | 74 | 72 | 40 | 20 | 25 | 28 | - |
Vallejo | 38.1 | 85 | 122.3 | 93 | 67 | 90 | 66 | 88 | 66 | 84 | 64 | 70 | 68 | 23 | 28 | 33 | 36 | - |
Valyermo RS | 34.5 | 3600 | 117.9 | 100 | 67 | 96 | 66 | 95 | 66 | 91 | 65 | 70 | 68 | 41 | 12 | 19 | 24 | 3870 |
Van Nuys | 34.2 | 708 | 118.5 | 103 | 71 | 98 | 69 | 96 | 69 | 92 | 67 | 74 | 71 | 30 | 28 | 33 | 39 | 664 |
Vandenburg AFB | 34.7 | 368 | 122.8 | 85 | 62 | 77 | 61 | 75 | 61 | 71 | 60 | 64 | 62 | 16 | 30 | 35 | 37 | 3451 |
Ventura | 34.3 | 341 | 119.3 | 89 | 68 | 82 | 67 | 80 | 67 | 76 | 66 | 70 | 68 | 15 | 29 | 34 | 36 | - |
Victorville Pumps | 34.5 | 2858 | 117.3 | 105 | 67 | 101 | 65 | 100 | 64 | 97 | 62 | 70 | 68 | 39 | 14 | 24 | 27 | 3191 |
View Park | 34 | 300 | 118.3 | 95 | 69 | 88 | 68 | 85 | 68 | 78 | 66 | 71 | 69 | 18 | 36 | 40 | 43 | - |
Villa Park | 33.8 | 300 | 117.8 | 99 | 70 | 92 | 68 | 90 | 68 | 85 | 67 | 72 | 70 | 27 | 33 | 37 | 40 | 550 |
Vincent | 34.5 | 3135 | 118.1 | 105 | 67 | 101 | 65 | 100 | 65 | 96 | 64 | 71 | 69 | 33 | 10 | 18 | 22 | 1455 |
Visalia | 36.3 | 325 | 119.3 | 103 | 71 | 100 | 70 | 99 | 70 | 96 | 69 | 73 | 72 | 38 | 25 | 30 | 33 | 2459 |
Vista | 33.2 | 510 | 117.2 | 96 | 69 | 90 | 68 | 89 | 68 | 85 | 67 | 72 | 70 | 16 | 30 | 35 | 37 | - |
Volta PH | 40.5 | 2220 | 120.9 | 101 | 66 | 98 | 65 | 97 | 65 | 93 | 63 | 69 | 67 | 33 | 21 | 27 | 30 | - |
Walnut | 34 | 550 | 117.9 | 101 | 70 | 97 | 69 | 96 | 69 | 92 | 69 | 74 | 72 | 30 | 28 | 33 | 35 | - |
Walnut Creek | 37.9 | 245 | 122.1 | 100 | 69 | 94 | 67 | 92 | 67 | 87 | 66 | 71 | 69 | 32 | 23 | 29 | 31 | - |
Walnut Grove | 38.2 | 23 | 121.5 | 102 | 70 | 98 | 69 | 96 | 69 | 92 | 68 | 72 | 71 | 37 | 24 | 30 | 32 | - |
Walnut Park | 33.9 | 45 | 118.2 | 92 | 69 | 84 | 68 | 82 | 68 | 78 | 66 | 71 | 69 | 12 | 37 | 42 | 44 | 450 |
Warner Springs | 33.3 | 3180 | 116.6 | 100 | 67 | 95 | 66 | 94 | 66 | 91 | 65 | 71 | 69 | 40 | 15 | 22 | 26 | 3591 |
Wasco | 35.6 | 333 | 119.3 | 105 | 71 | 101 | 70 | 100 | 70 | 97 | 68 | 74 | 72 | 36 | 23 | 28 | 31 | 2466 |
Watsonville | 36.9 | 95 | 121.8 | 86 | 66 | 82 | 64 | 81 | 63 | 79 | 61 | 68 | 65 | 22 | 28 | 33 | 35 | 3418 |
Weaverville RS | 40.7 | 2050 | 122.9 | 100 | 67 | 95 | 66 | 93 | 65 | 89 | 63 | 69 | 67 | 46 | 10 | 17 | 22 | 4992 |
Weed FD | 41.4 | 3590 | 122.4 | 92 | 63 | 89 | 62 | 88 | 61 | 84 | 59 | 65 | 63 | 35 | 4 | 12 | 17 | - |
West Athens | 33.9 | 25 | 118.3 | 92 | 69 | 85 | 68 | 84 | 68 | 80 | 66 | 71 | 69 | 18 | 32 | 37 | 39 | 450 |
West Carson | 33.8 | 100 | 118.3 | 92 | 69 | 87 | 68 | 85 | 68 | 81 | 66 | 71 | 69 | 18 | 32 | 37 | 39 | - |
West Compton | 33.9 | 71 | 118.3 | 97 | 69 | 90 | 68 | 88 | 68 | 83 | 67 | 72 | 70 | 21 | 33 | 37 | 39 | 450 |
West Covina | 34 | 365 | 117.9 | 102 | 70 | 98 | 69 | 96 | 69 | 92 | 68 | 74 | 72 | 34 | 29 | 34 | 36 | - |
West Hollywood | 34 | 290 | 118.4 | 95 | 70 | 89 | 69 | 87 | 69 | 82 | 67 | 72 | 70 | 20 | 38 | 42 | 45 | - |
West Pittsburg | 38 | 12 | 121.9 | 102 | 70 | 97 | 68 | 95 | 68 | 90 | 67 | 72 | 70 | 34 | 26 | 32 | 35 | - |
West Puente Valley | 34 | 500 | 117.9 | 101 | 71 | 97 | 70 | 95 | 70 | 91 | 68 | 73 | 71 | 26 | 31 | 36 | 39 | - |
West Sacramento | 38.6 | 19 | 121.5 | 104 | 72 | 100 | 70 | 98 | 70 | 94 | 68 | 74 | 71 | 35 | 26 | 31 | 33 | 1290 |
West Whittier-Los Nietos | 34 | 320 | 118.1 | 99 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 24 | 31 | 35 | 38 | - |
Westlake Village | 34.2 | 750 | 118.8 | 103 | 71 | 99 | 70 | 98 | 70 | 94 | 69 | 73 | 71 | 26 | 26 | 30 | 33 | - |
Westminster | 33.8 | 38 | 118 | 95 | 70 | 88 | 68 | 86 | 68 | 81 | 67 | 72 | 70 | 23 | 33 | 38 | 41 | - |
Westmont | 33.9 | 110 | 118.3 | 96 | 70 | 89 | 69 | 87 | 69 | 83 | 67 | 72 | 70 | 20 | 36 | 41 | 44 | 400 |
Whiskeytown Res | 40.6 | 1295 | 122.6 | 105 | 69 | 101 | 68 | 100 | 68 | 96 | 67 | 72 | 70 | 31 | 25 | 30 | 33 | - |
White Mtn 1 | 37.5 | 10150 | 119.3 | 73 | 49 | 69 | 47 | 68 | 47 | 65 | 45 | 53 | 50 | 37 | -15 | -9 | -6 | - |
White Mtn 2 | 37.6 | 12470 | 119.3 | 61 | 42 | 58 | 41 | 57 | 41 | 54 | 40 | 46 | 43 | 38 | -20 | -15 | -12 | - |
Whittier | 34 | 320 | 118 | 99 | 69 | 90 | 68 | 88 | 68 | 84 | 67 | 72 | 70 | 24 | 31 | 35 | 38 | - |
Wildomar | 33.6 | 1255 | 117.3 | 103 | 70 | 99 | 69 | 98 | 69 | 94 | 68 | 74 | 72 | 36 | 23 | 28 | 30 | 827 |
Wildrose RS | 36.3 | 4100 | 100 | 64 | 97 | 63 | 96 | 63 | 93 | 61 | 68 | 66 | 33 | 13 | 20 | 24 | - | |
Williams | 39.2 | 85 | 122.2 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 36 | 24 | 29 | 32 | - |
Willits | 39.4 | 1350 | 123.3 | 95 | 66 | 89 | 65 | 87 | 64 | 82 | 62 | 68 | 66 | 38 | 18 | 24 | 27 | - |
Willow Brook | 33.9 | 60 | 118.2 | 97 | 70 | 90 | 69 | 88 | 69 | 83 | 67 | 72 | 70 | 21 | 35 | 39 | 42 | - |
Willow Creek | 41 | 461 | 123 | 104 | 70 | 98 | 68 | 96 | 68 | 92 | 66 | 71 | 69 | 35 | 22 | 28 | 31 | - |
Willows | 39.5 | 140 | 122.2 | 104 | 71 | 100 | 70 | 98 | 70 | 94 | 68 | 73 | 71 | 36 | 22 | 28 | 31 | 2836 |
Windsor | 38.5 | 130 | 122.8 | 99 | 69 | 96 | 68 | 95 | 68 | 92 | 66 | 71 | 69 | 35 | 24 | 27 | 29 | 1249 |
Winters | 38.5 | 135 | 122 | 104 | 71 | 99 | 70 | 97 | 70 | 93 | 68 | 73 | 71 | 38 | 24 | 29 | 32 | 2593 |
Winton | 37.4 | 168 | 120.6 | 103 | 71 | 100 | 69 | 99 | 69 | 95 | 67 | 73 | 71 | 36 | 21 | 27 | 30 | 1244 |
Woodcrest | 33.9 | 1500 | 117.4 | 104 | 70 | 100 | 69 | 99 | 68 | 95 | 65 | 74 | 72 | 37 | 27 | 32 | 35 | 611 |
Woodfords | 38.8 | 5671 | 119.8 | 92 | 59 | 89 | 58 | 88 | 58 | 84 | 56 | 63 | 61 | 32 | 0 | 5 | 12 | 6047 |
Woodlake | 36.3 | 500 | 119.1 | 103 | 71 | 100 | 70 | 99 | 70 | 96 | 69 | 73 | 72 | 38 | 25 | 30 | 33 | 1130 |
Woodland | 38.7 | 69 | 121.8 | 106 | 72 | 101 | 71 | 100 | 71 | 96 | 69 | 74 | 72 | 40 | 25 | 30 | 33 | 2708 |
Woodland Hills | 34.2 | 944 | 118.6 | 104 | 71 | 99 | 70 | 97 | 70 | 93 | 68 | 74 | 72 | 32 | 26 | 31 | 34 | 664 |
Woodside | 37.5 | 75 | 122.3 | 92 | 67 | 84 | 66 | 82 | 65 | 76 | 63 | 69 | 67 | 24 | 22 | 28 | 31 | - |
Yorba Linda | 33.9 | 350 | 117.8 | 102 | 70 | 94 | 69 | 92 | 69 | 88 | 68 | 73 | 71 | 31 | 30 | 35 | 37 | 1643 |
Yosemite Park Hq | 37.7 | 3970 | 119.6 | 97 | 63 | 94 | 62 | 93 | 62 | 90 | 60 | 67 | 65 | 38 | 11 | 18 | 23 | 4785 |
Yreka | 41.7 | 2625 | 122.6 | 99 | 66 | 95 | 65 | 94 | 65 | 90 | 64 | 69 | 67 | 39 | 8 | 15 | 20 | 5395 |
Yuba City | 39.1 | 70 | 121.6 | 105 | 69 | 101 | 69 | 100 | 69 | 96 | 68 | 72 | 71 | 36 | 24 | 29 | 32 | - |
Yucaipa | 34 | 2600 | 117 | 106 | 68 | 102 | 67 | 101 | 67 | 98 | 65 | 73 | 71 | 35 | 27 | 32 | 35 | - |
Yucca Valley | 34.2 | 2600 | 116.4 | 108 | 71 | 105 | 70 | 104 | 70 | 101 | 69 | 75 | 73 | 32 | 19 | 24 | 27 | 862 |
*Heating Degree Day is a unit, based on temperature difference and time, used in estimating fuel consumption and specifying nominal annual heating load of a building. For any one day when the mean temperature is less than 65ºF (18ºC), there exist as many degree days as there are Fahrenheit degrees difference in temperature between mean temperature for the day and 65ºF (18ºC).
KEY TO ABBREVIATIONS:
AFB | Air Force Base |
AFS | Air Force Station |
AP | Airport |
CO | City/County Office |
FD | Fire Department |
FS | F ire Station |
MCB | Marine Corps Base |
MCWB | Mean Coincident Wet Bulb |
NAS | Naval Air Station |
NM | National Monument |
PH | Power House |
RS | Ranger Station |