You are currently viewing the Staging Site.
9.3 Performance Approach Compliance for Photovoltaic Systems
9.3.1 Energy Budget Calculation

The performance approach allows for modeling of the PV system performance by taking into account the PV system size, climate, panel orientation, panel and inverter efficiency, and shading characteristics. For nonresidential and hotel/motel buildings, the standard design PV system size is determined by the smaller of the PV system size determined by Equation 9-1, or the total of all available Solar Access Roof Areas (SARAs) multiplied by 14 W/ft². The performance method allows for modeling different PV sizes, solar thermal systems, more energy efficiency measures, additional battery storage and other demand-response measures.

9.3.2 Exceptions to PV Requirements

The allowable exceptions to the prescriptive PV requirements listed in 9.2., for nonresidential, hotel/motel and high-rise multifamily buildings or low-rise multifamily buildings, respectively, can also be used under the performance approach. The user must select the appropriate exception in the software and provide documentation to the building department with the building permit application.

9.3.3 Additional Requirements

The installed PV system must meet the applicable requirements specified in JA11.


Example 9-5: Efficiency Tradeoff

Question:

Does the performance path allow tradeoffs between PV systems and energy efficiency measures? How about tradeoffs between a PV system that is coupled with a battery storage system and energy efficiency measures?

Answer:

Beginning with the 2019 Standards, the performance path no longer allows installing a larger PV system in exchange for less energy efficiency measures for showing compliance with the TDV energy-based compliance metrics; however, the software will allow installing more energy efficiency, demand-responsive measures; battery and storage; and thermal storage systems in exchange for a smaller PV system. Larger PV systems can gain compliance credit for the hourly source energy-based metrics.

Example 9-6 Solar Thermal System

Question:

Does a solar thermal water heating system still qualify for compliance credit in the performance path?

Answer:

Yes, although a solar water heating system cannot serve as a substitution for the prescriptively required PV system, it can still be installed along with PV for optional compliance credit in the performance path. Solar water heating systems are modeled along with the remainder of the water heating and distribution systems and can be used for trading off efficiency measures or installing a smaller PV system. The requirements for solar thermal water heating systems are described in Chapter 4, Water Heating Requirements.


This panel displays referenced content when certain links are clicked.

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2025 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.