8.4 Subdivisions and Master Plans

Subdivisions often require a special approach to energy compliance because they have one or a few basic building or unit plans repeated in a variety of orientations. The basic floor plans may also be used in a mirrored or reversed configuration.

There are two compliance options for subdivisions:

  • Model each individual building, or building condition, separately according to the actual orientation.
  • Model all four cardinal orientations for each building or plan type with identical conservation features for no orientation restrictions.
8.4.1 Individual Building Approach

The most straightforward option for subdivisions is analyzing each building in the project separately using any compliance method. This may be practical for subdivisions with only custom buildings, or with only one or two specific orientations for each building plan. This approach requires that each unit comply separately, with separate documentation submitted for each unit plan in the orientation in which it will be constructed.

8.4.2 Multiple Orientation Alternative: No Orientation Restrictions

ยง150.1(b) 


The performance method may be used to demonstrate that a building plan complies regardless of its orientation within the same climate zone. To ensure compliance in any orientation, the annual energy consumption must be calculated using all four cardinal orientations (a single CF1R with results for north, east, south, and west). The building must have the identical efficiency measures and levels, and comply with the energy budget in all orientations. Cardinal compliance can be used to show compliance for a reversed floor plan.

Figure 8-2: Subdivisions and Master Plans Compliance Option

Figure of a subdivision and master plans compliance option

Demonstrate Compliance for Each Cardinal Orientation for Each Basic Model Type

Source: California Energy Commission

For compliance, submit certificate of compliance documentation of the energy budgets for each of the four orientations to the enforcement agency. Only one CF1R compliance document that shows compliance for all four orientations is required to be submitted to the enforcement agency for each unique or reverse plan.

Master plans that use the multiple orientation alternative must establish a connection to the CF1R in the HERS registry. For the multiple orientation compliance approach in a master plan subdivision, the required documentation for each dwelling unit should be a multiple orientation master plan certificate of compliance (CF1R), a dwelling-specific certificate of installation (CF2R), and a dwelling-specific certificate of verification (CF3R).

This panel displays referenced content when certain links are clicked.

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2025 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.