You are currently viewing the Staging Site.
3.1 Overview

This chapter covers building envelope features and compliance strategies and highlights the Energy Code requirements that affect the design of the building envelope for newly constructed single family residential buildings. See Chapter 9 for information on alterations and additions.

The design of envelope components can significantly affect the energy demand needed to meet heating and cooling loads to maintain the desired internal building temperature.

Heating and cooling load calculations are used to determine the mechanical system design needed for space heating and cooling.

  • Heating Loads: The principal components of heating loads are infiltration and conduction losses through building envelope components, including walls, roofs, floors, slabs, windows, and doors.
    • Example: A dwelling unit located in climate zone 16 typically has a large heating load due to moderate summers, cool temperatures, and snow cover that predominates for more than half of the year.
  • Cooling Loads: Cooling loads are dominated by solar gains through windows, skylights, and roof/attic assemblies.
    • Example: A dwelling unit located in climate zone 15 typically has a large cooling load due to extremely hot and dry summers and moderately cold winters.
3.1.1 Navigating This Chapter

This chapter is organized by building envelope component as seen in the Table of Contents.

This chapter includes:

  • An overview of changes to building envelope requirements for the 2022 Energy Code
  • A description of fenestration terminology, requirements and labeling, U-factor and solar heat gain coefficient (SHGC) requirements, and credits that can be used under the performance approach
  • Description of opaque envelope terminology, requirements related to insulation, roof products, radiant barriers, air barriers, vapor retarders, and attic ventilation
  • Compliance approaches for alternative construction assemblies such as log homes, straw bale, structural insulated panels (SIPs) and insulated concrete form (ICF) construction

This panel displays referenced content when certain links are clicked.

This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2025 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.